Do not make voltage measurements on industry power lines
of 250V or higher.
Kyoritsu Indonesia-Analog Multimeter 1109S
Written By Anonymous on August 09, 2012 | 1:15 PM
Kyoritsu Indonesia - Analogue Multimeters
KEW 1109S
• Mirrored scale for easy and accurate reading.
• Output terminal to cut off DC component when measuring AC voltage.
• Safety designed input terminals and test leads.
• Output terminal to cut off DC component when measuring AC voltage.
• Safety designed input terminals and test leads.
of 250V or higher.
| DC V | 0.1/0.5/2.5/10/50/250/1000V ±3% of FS (20kΩ/V) |
|---|---|
| AC V | 10/50/250/1000V (9kΩ/V) ±3% of FS |
| DC A | 50µA/2.5/25/250mA ±3% of FS |
| Ω | 2/20kΩ/2/20MΩ ±3% of scale length |
| Decibel | -10 - +62dB |
| hFE | 0 - 1000 (Ω × 10) ±3% of scale length |
| Power source | R6 (AA) (1.5V) × 2 6F22 (9V) × 1 |
| Dimensions | 150(L) × 100(W) × 47(D)mm |
| Weight | 330g approx. |
| Included Accessories | 7066A (Test leads) 8901 (Fuse [0.5A/250V]) × 2 R6 (AA) × 2 6F22 × 1 Instruction Manual |
| Optional Accessories | 9168 (Carrying Case) |
Accessories/Optional Accessories /Related Products
-

- MODEL 7066A
1:10 PM
Kyoritsu Indonesia - Digital Multimeter 1009
Kyoritsu Indonesia - Digital Multimeters
MODEL 1009
• Display : 4000 counts.
• Auto range and manual range selector provided.
(with range hold feature)
• Resistance range provides audible continuity test.
• Automatically turns power off in about 30 minutes to conserve battery life.
• Direct current measurement up to 10A AC and DC.
• With Holster.
• Auto range and manual range selector provided.
(with range hold feature)
• Resistance range provides audible continuity test.
• Automatically turns power off in about 30 minutes to conserve battery life.
• Direct current measurement up to 10A AC and DC.
• With Holster.
| DC V | 400mV/4/40/400/600V (Input Impedance 10MΩ) ±0.6%rdg±4dgt (400mV/4/40/400V) ±1.0%rdg±4dgt (600V) |
|---|---|
| AC V | 400mV/4/40/400/600V (Input Impedance 10MΩ) ±1.6%rdg±4dgt (20 - 400mV) ±1.3%rdg±4dgt (4/40V) ±1.6%rdg±4dgt (400/600V) |
| DC A | 400/4000µA/40/400mA/4/10A ±2.0%rdg±4dgt (400/4000µA)±1.0%rdg±4dgt (40/400mA) ±1.6%rdg±4dgt (4/10A) |
| AC A | 400/4000µA/40/400mA/4/10A ±2.6%rdg±4dgt (400/4000µA) ±2.0%rdg±4dgt (40/400mA/4/10A) |
| Ω | 400Ω/4/40/400kΩ/4/40MΩ ±1.0%rdg±4dgt (400Ω/4/40/400kΩ/4MΩ) ±2.0%rdg±4dgt (40MΩ) |
| Continuity buzzer | 400Ω (Buzzer sounds below 100Ω) |
| Diode test | 1.5V Release Voltage:Approx. 0.4mA Test Current |
| Capacitance | 40/400nF/4/40/100µF |
| Frequency | 5.12/51.2/512Hz/5.12/51.2/512kHz/5.12/10MHz |
| DUTY | 0.1 - 99.9% (Pulse width/Pulse period) ±2.5%±5dgt |
| Applicable standards | IEC 61010-1 CAT III 300V IEC 61010-2-031 IEC 61326 |
| Power source | R6 (1.5V) × 2 |
| Dimensions | 161(L) × 82(W) × 50(D)mm |
| Weight | Approx. 280g |
| Included Accessories | 7066A (Test leads) 8919 (Ceramic fuse [10A/600V])× 1 8923 (Fuse [0.5A/600V])× 1 R6× 2 Instruction Manual |
| Optional Accessories | 7234 (Crocodile clip test lead) 9095 (Carrying case) |
Accessories/Optional Accessories /Related Products
-

- MODEL 7066A
-

- MODEL 7234
-

- MODEL 9095
1:05 PM
• Double moulding provides comfortable and good feeling in hand.
• Penlight illuminates brightly the point to be measured, even in dark place.
• Backlight LCD is highly visible, even in darkness.
• Unique wrapping mechanism for test lead in the rear side compartment.
• Unique protection mechanism for the test prod for safety.
• All ranges including Ohm range are protected against overload voltage of 600V.
* Length of test lead is adjustable in 3 steps, ie, 60cm, 40cm and 20cm.
Kyoritsu Indonesia - Digital Multimeter 1030
Kyoritsu Indonesia - Digital Multimeters
KEW 1030
• Compact in Size, Light in Weight and Simple in Use.
• Double moulding provides comfortable and good feeling in hand.
• Penlight illuminates brightly the point to be measured, even in dark place.
• Backlight LCD is highly visible, even in darkness.
• Unique wrapping mechanism for test lead in the rear side compartment.
• Unique protection mechanism for the test prod for safety.
• All ranges including Ohm range are protected against overload voltage of 600V.
| ■Long life LED light is of good use in dark place | ■Protection cover prevents unforeseen accident |
![]() |
|
| ■Wrapping mechanism for test lead in rear side compartment | |
![]() |
|
| DC V | 400m/4/40/400/600V (5 Range auto) ±0.8%rdg ±5dgt(400mV - 400V) ±1.0%rdg ±5dgt(600V) |
|---|---|
| AC V | 4/40/400/600V (4 Range auto) ±1.3%rdg ±5dgt (4/40V) (50/60Hz) ±1.6%rdg ±5dgt (400/600V) (50/60Hz) |
| Ω | 400/4k/40k/400k/4M/40MΩ (6 Range auto) ±1.0%rdg ±5dgt (400Ω - 4MΩ) ±2.5%rdg ±5dgt (40MΩ) |
| Continuity buzzer | Buzzer sounds when resistance is 120Ω or less. |
| Diode test | Test voltage approx. 0.3 - 1.5V |
| Capacitance | 50n/500n/5µ/50µ/100µF (5 Range auto) ±3.5%rdg ±10dgt (50nF) ±3.5%rdg ±5dgt (500n - 50µF) ±4.5%rdg ±5dgt (100µF) |
| Frequency | 5/50/500/5k/50k/200kHz ±0.1%rdg ±5dgt (Measurable input: 1.5Vrms or more) |
| DUTY | 0.1 - 99.9% ±2.5%rdg ±5dgt (Pulse width / Pulse cycle) |
| Measurement functions | The measured value can be hold by pressing Data hold button |
| Other functions | When the battery voltage drops to 2.4V±0.2V or less Built-in |
| Applicable standards | IEC 61010-1: 2001 CAT III 600V IEC 61010-031 IEC 61326-1 |
| Power source | Button type battery LR44 (SR44)1.5V × 2 |
| Dimensions | 190(L) × 39(W) × 31(D)mm |
| Weight | Approx. 100g (including batteries |
| Included Accessories | Carrying case, LR44 (1.5V) × 2, Instruction manual |
12:58 PM
Kyoritsu Indonesia - Digital Multimeter 1012
Kyoritsu Indonesia - Digital Multimeters
KEW 1012
• True RMS can measure and indicate distorted waveforms
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min & max value
• REL(relative value) function to indicate the measurement variation
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min & max value
• REL(relative value) function to indicate the measurement variation
| DC V | 600.0mV/6.000/60.00/600.0/600V (Input Impedance: 10MΩ, 100MΩ only 600mV) ±0.5%±2dgt (600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt (600V) |
|---|---|
| AC V | 6.000/60.00/600.0/600V (Input Impedance: 10MΩ) ±1.5%±5dgt (6.000V) ±1.2%±3dgt (60.00/600.0V) ±1.5%±5dgt (600V) |
| DC A | 600/6000µA/60/600mA/6/10A ±1.2%±3dgt (600/6000µA/60/600mA) ±2.0%±5dgt (6/10A) |
| AC A | 600/6000µA/60/600mA/6/10A ±1.5%±4dgt (600/6000µA/60/600mA) ±2.2%±5dgt (6/10A) |
| Ω | 600Ω/6/60/600kΩ/6/60MΩ ±1.0%±2dgt (600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt (60MΩ) |
| Continuity buzzer | 0 - 600Ω (Buzzer sounds below 100Ω) |
| Diode test | 2.8V Release Voltage:Approx. 0.4mA Test Current |
| Capacitance | 40/400nF/4/40/400/4000µF |
| Frequency | 10/100/1000Hz/10/100/1000kHz/10MHz |
| DUTY | 0.1 - 99.9% (Pulse width/Pulse period) ±2.0%±2dgt (- 10kHz) |
| Applicable standards | IEC 61010-1 CAT III 300V Pollution degree 2 IEC 61010-1 CAT II 600V Pollution degree 2 IEC 61010-031 IEC 61326 |
| Display | 6040 Counts |
| Power source | R6 (1.5V) × 2 (Auto-power-OFF within 15 minutes) |
| Dimensions | 161(L) × 82(W) × 50(D)mm |
| Weight | Approx. 280g |
| Included Accessories | 7066A (Test leads) 0.8A/600V (Ceramic Fuse) × 1built-in 10A/600V (Ceramic Fuse) × 1built-in R6 × 2 Instruction Manual |
| Optional Accessories | 7234 (Crocodile clip test lead) 9095 (Carrying case) |
Accessories/Optional Accessories /Related Products
- MODEL 7066A
-

- MODEL 7234
-