Kyoritsu Earth Testers
Latest Post
Showing posts with label LeCroy Indonesia. Show all posts
Showing posts with label LeCroy Indonesia. Show all posts
11:54 AM
Explore WaveExpert

Eye pattern analysis is the primary method of signal integrity
testing for optical signals and the WaveExpert performs this analysis
over 20 times faster than conventional sampling oscilloscopes.
A maximum bandwidth of 100 GHz along with a 230 fsrms noise floor enables measurements on the fastest optical signals.
The low jitter noise floor of the HCIS timebase along with LeCroy’s
innovative Q-Scale jitter analysis provides over 3 times the accuracy
over conventional sampling scope methods for all jitter types.
The standard TDR analysis package included with the WaveExpert 100H
offers full reference plane calibration and 1 and 2 port differential
S-parameter measurement fully integrated into the instrument interface.
The Virtual Probing and equalized receiver emulation features in the
Eye Doctor package provide full end-to-end signal integrity analysis of
serial data systems employing equalization.
WaveExpert Sampling Oscilloscopes - LeCroy Indonesia
Written By Anonymous on January 16, 2013 | 11:54 AM
Agen Resmi Teledyne LeCroy Indonesia
WaveExpert Sampling Oscilloscopes
The ideal signal integrity analysis solution for high-speed links. Measurement complexity and the emergence of receiver equalization which allows high-speed serial data links to operate error-free even when the signal is severely distorted requires WaveExpert's high bandwidth and detailed analysis capability.Explore WaveExpert
WaveExpert 100H ( 100 GHz Bandwidth, Max Sample Rate )
Check up to three models.
Ultra-High Bandwidth Signal Analysis
A maximum bandwidth of 100 GHz along with a 230 fsrms noise floor enables measurements on the fastest optical signals.
Highly Accurate Jitter Analysis
Up to 20 GHz TDR with Full S-parameter Measurements
Eye Doctor™ Offers Virtual Probing and Equalized Signals
11:50 AM
Explore LabMaster 10 Zi

The LabMaster class of oscilloscopes are fundamentally better – they are modular, inherently upgradeable, and infinitely flexible while retaining all of the simplicity of operation that you expect from a conventional oscilloscope. LabMaster 10 Zi oscilloscopes can be configured for massive numbers of channels at up to 65 GHz – truly eliminating your technology and test barriers.
LeCroy’s ChannelSync architecture ensures precise synchronization of all acquisition modules. ChannelSyn ensures precise synchronization of all channels in all acquisition modules by using a single-distributed 10 GHz clock and a single trigger circuit. External clocking is not required, and trigger jitter from multiple trigger circuits is non-existent. Jitter between all channels is an ultra-low <275 fsrms,. Synchronization performance is identical to that provided with a single, standard oscilloscope package, and all captured waveforms and analysis appears on one oscilloscope display.
LabMaster 10 Zi is perfect for developed and emerging 10-12 Gb/s technologies, such as 40/100 GBASE-R Ethernet and SAS12, benefit from 80 GS/s on four (or more) channels at up to 36 GHz. Ultra-high speed technologies, such as CEI-25/28, CEI-56, and optical coherent modulation communication systems (DP-QPSK, 16-QAM, MIMO) benefit from the world’s fastest real-time bandwidth (65 GHz) and four or more channels. LeCroy's SDAIII-CompleteLinQ Serial Data and Crosstalk Analysis software provides even more capability for simulataneous multi-lane eye, jitter, vertical noise and crosstalk analysis.
LabMaster 10 Zi Oscilloscopes - LeCroy Indonesia
Agen Resmi Teledyne LeCroy Indonesia
LabMaster 10 Zi Oscilloscopes
The LabMaster 10 Zi is the world's highest bandwidth real-time oscilloscope - 65 GHz at 160 GS/s. LabMaster 10 Zi is also modular - it breaks channel count barriers and provides more "bandwidth density". The modular design provides the simplest upgrade path in bandwidth and channel count, with one acquisition module providing four channels at 36 GHz or two channels at 65 GHz, with capability for up to 20 acquisition modules .Explore LabMaster 10 Zi
LabMaster 10 Zi 25 GHz Systems (25 GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
LabMaster 10 Zi 30 GHz Systems (30 GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
LabMaster 10 Zi 36 GHz Systems (36 GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
LabMaster 10 Zi 50 GHz Systems (50
GHz Bandwidth, Up to 40 Input Channels, 160 GS/s Max Sample Rate; 36
GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
LabMaster 10 Zi 60 GHz Systems (60
GHz Bandwidth, Up to 40 Input Channels, 160 GS/s Max Sample Rate; 36
GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
LabMaster 10 Zi 65 GHz Systems (65
GHz Bandwidth, Up to 40 Input Channels, 160 GS/s Max Sample Rate; 36
GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Check up to three models.
Quick Specs
The Ultimate in High Bandwidth Performance
- Up to 65 GHz
- Up to 80 Channels @ 36 GHz
- Up to 160 GS/s
- Up to 1024 Mpts/Ch
- Multi-channel operation at the highest bandwidths
- 40 channels @ 65 or 50 GHz
- 80 channels @ 36, 30, or 25 GHz
- Bandwidth and channel upgrade flexibility
- ChannelSync for precise synchronization of all acquisition modules
- Server-class CPU (33.6 GHz effective clock rate, up to 192 GB RAM)
- Ultra-low jitter noise floor (100 fs rms) and ultra-high time base stability.
- 5.2 ps (20-80%) rise time
- 14.1 Gb/s hardware serial trigger (28 Gb/s in development)
The LabMaster class of oscilloscopes are fundamentally better – they are modular, inherently upgradeable, and infinitely flexible while retaining all of the simplicity of operation that you expect from a conventional oscilloscope. LabMaster 10 Zi oscilloscopes can be configured for massive numbers of channels at up to 65 GHz – truly eliminating your technology and test barriers.
LeCroy’s ChannelSync architecture ensures precise synchronization of all acquisition modules. ChannelSyn ensures precise synchronization of all channels in all acquisition modules by using a single-distributed 10 GHz clock and a single trigger circuit. External clocking is not required, and trigger jitter from multiple trigger circuits is non-existent. Jitter between all channels is an ultra-low <275 fsrms,. Synchronization performance is identical to that provided with a single, standard oscilloscope package, and all captured waveforms and analysis appears on one oscilloscope display.
LabMaster 10 Zi is perfect for developed and emerging 10-12 Gb/s technologies, such as 40/100 GBASE-R Ethernet and SAS12, benefit from 80 GS/s on four (or more) channels at up to 36 GHz. Ultra-high speed technologies, such as CEI-25/28, CEI-56, and optical coherent modulation communication systems (DP-QPSK, 16-QAM, MIMO) benefit from the world’s fastest real-time bandwidth (65 GHz) and four or more channels. LeCroy's SDAIII-CompleteLinQ Serial Data and Crosstalk Analysis software provides even more capability for simulataneous multi-lane eye, jitter, vertical noise and crosstalk analysis.
11:49 AM
Explore LabMaster 9 Zi-A

Upgrade flexibility is designed in—start with a minimum configuration and add channels over time by simply adding additional acquisition modules, upgrade bandwidth on existing modules, or mix and match bandwidths in one system. A server-class CPU packs additional processing power for the immense amounts of data made possible by LabMaster 9 Zi-A.
LabMaster enables the leading-edge technologies that provide enhanced high speed data transfer and communication—such as 28 – 32 Gb/s SERDES, multi-lane serial data (40/100 GbE, PCIe Gen3), DDR, and optical coherent modulation communications. It's also ideal for defense and aerospace applications where high channel count and high bandwidth are both required.
LabMaster 9 Zi-A Oscilloscopes - LeCroy Indonesia
Agen Resmi Teledyne LeCroy Indonesia
LabMaster 9 Zi-A Oscilloscopes
The LabMaster 9 Zi-A builds on the acquisition and analysis excellence of the LeCroy WaveMaster 8 Zi-A oscilloscopes, but uses a modular design to provide massive numbers of channels (up to 80 channels at up to 20 GHz), up to five channels at 45 GHz, or something in between. Maximum sample rate is 120 GS/s with maximum analysis memory of 768 Mpts/Ch. LabMaster 9 Zi-A oscilloscopes have pioneered next-generation research and development in optical transmission, high speed SERDES, and multi-lane serial data transmissions.Explore LabMaster 9 Zi-A
LabMaster 9 Zi-A 13 GHz Systems (13 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
LabMaster 9 Zi-A 16 GHz Systems (16 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
LabMaster 9 Zi-A 20 GHz Systems (20 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
LabMaster 9 Zi-A 30 GHz Systems (30 GHz Bandwidth, Up to 40 Input Channels, 80 GS/s Max Sample Rate, 20 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max )
Quick Specs
LabMaster 9 Zi-A 36 GHz Systems (36 GHz Bandwidth, Up to 40 Input Channels, 80 GS/s Max Sample Rate, 20 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max )
Quick Specs
LabMaster 9 Zi-A 45 GHz Systems (45
GHz Bandwidth, Up to 20 Input Channels, 120 GS/s Max Sample Rate; 30
GHz Bandwidth, Up to 40 Input Channels, 80 GS/s Max Sample Rate, 20 GHz
Bandwidth, Up to 80 Input Channels, 40 GS/s Max )
Check up to three models.
Quick Specs
The Ultimate in Performance
- Up to 45 GHz
- Up to 80 Channels @ 20 GHz
- Up to 120 GS/s
- Up to 768 Mpts/Ch
- Multi-channel operation at the highest bandwidths
- 20 channels @ 45 GHz
- 40 channels @ 36 GHz
- 80 channels @ 20, 16, or 13 GHz
- Bandwidth and channel upgrade flexibility
- ChannelSync for precise synchronization of all acquisition modules
- Server-class CPU (33.6 GHz effective clock rate, up to 192 GB RAM)
- Ultra-low jitter noise floor (125 fs rms) and ultra-high time base stability.
Upgrade flexibility is designed in—start with a minimum configuration and add channels over time by simply adding additional acquisition modules, upgrade bandwidth on existing modules, or mix and match bandwidths in one system. A server-class CPU packs additional processing power for the immense amounts of data made possible by LabMaster 9 Zi-A.
LabMaster enables the leading-edge technologies that provide enhanced high speed data transfer and communication—such as 28 – 32 Gb/s SERDES, multi-lane serial data (40/100 GbE, PCIe Gen3), DDR, and optical coherent modulation communications. It's also ideal for defense and aerospace applications where high channel count and high bandwidth are both required.
11:48 AM

WaveMaster 8 Zi-A Oscilloscopes - LeCroy Indonesia
Agen Resmi Teledyne LeCroy Indonesia
WaveMaster 8 Zi-A Oscilloscopes
World's Highest Bandwidth Real-time Oscilloscope with Superior Performance
WaveMaster 8 Zi-A combines the highest bandwidth (45 GHz) and sample
rate (120 GS/s) with superior signal fidelity performance and 20 GHz on
all four input channels. Models are available from 4 to 45 GHz with
complete bandwidth upgradability throughout the range. The X-Stream II
architecture maximizes speed in all aspects and provides for full
analysis on maximum record lengths using LeCroy's flexible and deep
analysis toolbox. Explore WaveMaster 8 Zi-A
WaveMaster 804Zi-A (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 806Zi-A (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 808Zi-A (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 813Zi-A (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 816Zi-A (16 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 820Zi-A (20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 825Zi-A (25 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 830Zi-A (30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
WaveMaster 845Zi-A (45
GHz Bandwidth, 1 Input Channel, 120 GS/s Max Sample Rate; 30 GHz
Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4
Input Channels, 40 GS/s Max Sample Rate)
Check up to three models.
Quick Specs
45 GHz Real-Time Bandwidth
LeCroy has again broken bandwidth barriers by utilizing widely
adopted and proven SiGe processes, custom 2nd generation ASIC designs,
and 6th generation Digital Bandwidth Interleave (DBI) technology to
achieve unprecedented real-time oscilloscope performance:- 45 GHz
- 120 GS/s
- 768 Mpts/Ch Analysis Memory
20 GHz/4ch Model
Four channel performance at 20 GHz is pristine with exceptional rise
time, overshoot, total and random jitter noise floor, and electrical
noise performance.
LeCroy — The Analysis Memory Leader
LeCroy has found a way to make long acquisition memory seamless and
pain free to use. The WaveMaster 8 Zi-A Series' proprietary X-Stream II
architecture supports capturing, zooming, measuring and analyzing
multiple waveforms at up to 768 Mpts deep. WaveMaster 8 Zi-A's
proprietary architecture design is augmented with an Intel® Core™ 2 Quad
processor (12 GHz effective clock rate), high-speed serial data buses,
Windows 7 64-bit OS and 8 GB of RAM. What you experience is processing
speed 10-100x faster compared to other oscilloscopes in this class.
Highest Stability Timebase and Lowest Jitter Noise Floor
An exceptionally accurate and stable time base is incorporated for
the best possible jitter measurement accuracy jitter noise floor is as
low as 125 fsrms. LeCroy provides highly stable measurements at full
(768 Mpts) record lengths, simplifying debug of low frequency events.
Freedom from Probing Limitations
High bandwidth differential probes (up to 25 GHz), single-ended
active probes, current probes, high-voltage, and mixed signals all
connect to the WaveMaster 8 Zi-A oscilloscope and give you a total
system view. All WaveMaster 8 Zi-A oscilloscopes contain selectable 50
Ohm and 1 MOhm input capability and can be used with any LeCroy probe -
passive or active - without requiring external adapters or power
supplies.
11:45 AM
Explore SDA 8 Zi-A

SDA 8 Zi-A Serial Data Analyzers - LeCroy Indonesia
Agen Resmi Teledyne LeCroy Indonesia
SDA 8 Zi-A Serial Data Analyzers
SDA 8 Zi-A Serial Data Analyzers combine the highest bandwidth (45 GHz) and sample rate (120 GS/s) with superior performance at 20 GHz on all four input channels. Models are available from 4 to 45 GHz with complete bandwidth upgradability throughout the range. SDA 8 Zi-A models combine all the attributes of WaveMaster 8 Zi-A with additional capabilities specifically suited for serial data testing.Explore SDA 8 Zi-A
SDA 804Zi-A (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
SDA 806Zi-A (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
SDA 808Zi-A (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
SDA 813Zi-A (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
SDA 816Zi-A (16 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
SDA 820Zi-A (20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
SDA 825Zi-A (25 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
SDA 830Zi-A (30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
SDA 845Zi-A (45
GHz Bandwidth, 1 Input Channel, 120 GS/s Max Sample Rate; 30 GHz
Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4
Input Channels, 40 GS/s Max Sample Rate)
Check up to three models.
Quick Specs
45 GHz Real-Time Bandwidth
LeCroy has again broken bandwidth barriers by utilizing widely
adopted and proven SiGe processes, custom 2nd generation ASIC designs,
and 6th generation Digital Bandwidth Interleave (DBI) technology to
achieve unprecedented real-time oscilloscope performance:- 45 GHz
- 120 GS/s
- 768 Mpts/Ch Analysis Memory
20 GHz/4ch Model
Four channel performance at 20 GHz is pristine with exceptional rise
time, overshoot, total and random jitter noise floor, and electrical
noise performance. SDAII Serial Data Analysis Software LeCroy's SDAII
software is optimized for fast eye diagram creation on long records, and
deep insight of jitter pathologies with more parameters and analysis
views to help you understand the root cause of high jitter.
Additional Capability Standard
SDA 8 Zi-A models provide additional capability standard that costs extra in WaveMaster 8 Zi-A models, such as:- 32 Mpts/ch memory
- SDAII software
- JTA2 software
- SDM and ET-PMT software
- 8b10b decode
- High speed serial trigger
LeCroy—The Analysis Memory Leader
LeCroy has found a way to make long acquisition memory seamless and
pain free to use. The SDA 8 Zi-A Series' proprietary X-Stream II
architecture supports capturing, zooming, measuring and analyzing
multiple waveforms at up to 768 Mpts deep. SDA 8 Zi-A's proprietary
architecture design is augmented with an Intel® Core™ 2 Quad processor
(12 GHz effective clock rate), high-speed serial data buses, Windows 7
64-bit OS and 8 GB of RAM. What you experience is processing speed
10–100x faster compared to other oscilloscopes in this class.
Highest Stability Timebase and Lowest Jitter Noise Floor
An exceptionally accurate and stable time base is incorporated for
the best possible jitter measurement accuracy—jitter noise floor is as
low as 125 fsrms. LeCroy provides highly stable measurements at full
(768 Mpts) record lengths, simplifying debug of low frequency events.
Freedom from Probing Limitations
High bandwidth differential probes (up to 25 GHz), single-ended
active probes, current probes, high-voltage, and mixed signals all
connect to the SDA 8 Zi-A serial data analyzers and give you a total
system view. All SDA 8 Zi-A serial data analyzers contain selectable 50
Ohm and 1 MOhm input capability and can be used with any LeCroy
probe—passive or active—without requiring external adapters or power
supplies.
11:44 AM
Explore DDA 8 Zi-A

DDA 8 Zi-A Disk Drive Analyzers - LeCroy Indonesia
Agen Resmi Teledyne LeCroy Indonesia
DDA 8 Zi-A Disk Drive Analyzers
DDA 8 Zi-A models combine all the attributes of WaveMaster 8 Zi-A with additional capabilities specifically suited for disk drive and serial data testing.Explore DDA 8 Zi-A
DDA 808Zi-A (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
DDA 820Zi-A (20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
DDA 830Zi-A (30 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)
Check up to three models.
Quick Specs
20 GHz/4ch Model
Four channel performance at 20 GHz is pristine with exceptional rise
time, overshoot, total and random jitter noise floor, and electrical
noise performance.
SDAII Serial Data Analysis Software
LeCroy's SDAII software is optimized for fast eye diagram creation on
long records, and deep insight of jitter pathologies with more
parameters and analysis views to help you understand the root cause of
high jitter.
DDAII Disk Drive Analysis Software
LeCroy's DDAII software is specifically suited for disk drive analysis and is included standard in every DDA 8 Zi-A model.
Additional Capability Standard
DDA 8 Zi-A models provide additional capability standard that costs extra in WaveMaster 8 Zi-A models, such as:- 32 Mpts/ch memory
- SDAII software
- JTA2 software
- SDM and ET-PMT software
- 8b10b decode
LeCroy—The Analysis Memory Leader
LeCroy has found a way to make long acquisition memory seamless and
pain free to use. The DDA 8 Zi-A Series' proprietary X-Stream II
architecture supports capturing, zooming, measuring and analyzing
multiple waveforms at up to 512 Mpts deep. DDA 8 Zi-A's proprietary
architecture design is augmented with an Intel® Core™ 2 Quad processor
(12 GHz effective clock rate), high-speed serial data buses, Windows 7
64-bit OS and 8 GB of RAM. What you experience is processing speed
10–100x faster compared to other oscilloscopes in this class.
Highest Stability Timebase and Lowest Jitter Noise Floor
An exceptionally accurate and stable time base is incorporated for
the best possible jitter measurement accuracy—jitter noise floor is as
low as 140 fsrms. LeCroy provides highly stable measurements at full
(512 Mpts) record lengths, simplifying debug of low frequency events.
Freedom from Probing Limitations
High bandwidth differential probes (up to 25 GHz), single-ended
active probes, current probes, high-voltage, and mixed signals all
connect to the WaveMaster 8 Zi-A oscilloscope and give you a total
system view. All WaveMaster 8 Zi-A oscilloscopes contain selectable 50
Ohm and 1 MOhm input capability and can be used with any LeCroy
probe—passive or active—without requiring external adapters or power
supplies.
11:43 AM
Explore WavePro 7 Zi-A

WavePro
7 Zi-A excels in the way it offers general purpose utility never before
seen in oscilloscopes from 1.5 to 6 GHz. All WavePro 7 Zi-A
oscilloscopes contain selectable 50 Ω and 1 MΩ input capability. The 4
and 6 GHz models include both ProBus and ProLink input types which means
eight probes can be attached and then multiplexed from the front panel
or by remote control. The result— it's easy to hook up a passive probe
even on 4 or 6 GHz models—no more frustration and hassle of trying to
find a 1 MΩ input adapter. Plus, any existing investment in LeCroy
probes, such as current probes, single-ended or differential active
probes, or high voltage probes, is fully leveraged. Perfect.
TriggerScan
uses high-speed hardware triggering capability with persistence
displays to capture only the signals of interest and provide answers up
to 100X faster that other methods. Traditional fast display update modes
work best on frequent events occurring on slow edge rates while
TriggerScan excels in finding infrequent events on fast edge rates.
Add
Mixed Signal Oscilloscope (MSO) operation using the MS Series mixed
signal options. These convenient add-ons connect to the LeCroy LBUS and
quickly and simply provide capability to acquire up to 36 digital lines
time-correlated with analog waveforms. No time is wasted in trying to
learn how to connect, synchronize or operate a complicated logic
analyzer since the MSOs are already completely integrated into the scope
operation. In addition to acquiring digital lines, they are also
helpful for monitoring low-speed signals, such as serial data clock,
data, and chip select signals, thus preserving the analog channels for
higher speed requirements.
WavePro 7 Zi-A Oscilloscopes - LeCroy Indonesia
Agen Resmi Teledyne LeCroy Indonesia
WavePro 7 Zi-A Oscilloscopes
Combining signal fidelity with an architecture that maximizes speed in every performance aspect, the new WavePro 7 Zi-A Series presents a totally new oscilloscope experience from 1.5 to 6 GHz bandwidths. Experience 50 Ω and 1 MΩ inputs for every channel and four inputs into high-speed front end amplifiers and analog to digital converters. Experience the new X-Stream II architecture that provides 10 to 20 times faster long memory performance than any other oscilloscope. Combined with LeCroy’s flexible and deep analysis toolbox, the WavePro 7 Zi-A Series gives an unforgettable experience for the debugging, validation, analysis and compliance testing of electronic designs.Explore WavePro 7 Zi-A
WavePro 715Zi-A (1.5 GHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Quick Specs
WavePro 725Zi-A (2.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
WavePro 735Zi-A (3.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
WavePro 740Zi-A (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
WavePro 760Zi-A (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Check up to three models.
Quick Specs
Freedom from Limitations
More Triggers Isolate More Problems More Effectively
A powerful combination of high bandwidth Edge and 10 different
SMART triggers allow you to isolate the problem quickly and begin to
focus on the cause. Most SMART triggers allow triggering on pulse widths
or features as small as 200 ps. A high-speed serial trigger enables
triggering on up to 2.7 Gb/s serial patterns of up to 80-bits in length.
Built-in hardware clock recovery is also included.
TriggerScan™
WaveScan™ Advanced Search and Analysis Finds Problems that Triggers Won't Find
The best trigger won't find all unusual events—a more powerful
capability is sometimes needed. WaveScan provides the ability to locate
unusual events in a single capture (i.e., capture and search) or "scan"
for an event in many acquisitions over a long period of time. Select
from more than 20 search modes (frequency, rise time, runt, duty cycle,
etc.), apply a search condition and begin scanning. When an event is
found, WaveScan highlights the error on screen and displays a table
listing the errors.
Fully Integrated Mixed Signal Oscilloscope (4+36) Option
LeCroy — The Acquisition Memory Leader
LeCroy has found a way to make long acquisition memory seamless
and pain free to use. The WavePro 7 Zi Series' proprietary X-Stream II
architecture supports capturing, zooming, measuring and analyzing
multiple waveforms at 256 Mpts deep. What you experience is performance
gains of 10–20X over what is available today. Whether looking at the
acquired signal or while analyzing several screens of statistics,
tracking a frequency or identifying complex patterns the WavePro 7 Zi is
designed to perform.
Instantaneous Responsiveness
The first time you use the Zi oscilloscope you will experience
responsiveness that you've never seen before. Acquiring and manipulating
the longest record lengths and the most complex WaveShape Analysis are
all easily handled at the same time. Whether you use the front panel or
choose to make adjustments with a mouse or the touch screen, the system
performs.
X-Stream II Architecture
Optimized for Fast Throughput
Designed for long memory operation and responsiveness X-Stream
II technology enables high throughput of data—even when the oscilloscope
is performing multiple 100 Mpts waveforms. It does so by eliminating
the trade-offs between long memory length and quick processing. WavePro 7
Zi's proprietary architecture design is augmented with an Intel® Core™ 2
Quad processor, high-speed serial data buses, a 64-bit OS and up to 8
GB of RAM.
Optimized for Long Memory
By using variable waveform segment lengths to improve the CPU
cache memory efficiency the WavePro 7 Zi is designed for the fastest
processing of long waveform records. The result—10-20 times faster
processing compared to other oscilloscopes.
Optimized for Responsiveness
By dynamically allocating buffers where to maximize memory
availability the WavePro 7 Zi Series embodies the fastest front panel
responsiveness. Waveform previewing shows interim calculation results
while a built in processing abort make front panel control changes
instant by stopping the current process and allowing new waveforms to be
positioned or zoomed—all without a lengthy recalculation.
Digital Filter Software Package (WPZi-DFP2)
DFP2 lets you implement Finite or Infinite Impulse Response
filters to eliminate undesired spectral components, such as noise, and
enhances your ability to examine important signal components. You can
choose from a standared set of FIR or IIR filters. You can also design
your own filters.
Spectrum Analyzer Analysis Package (WPZi-SPECTRUM)
The spectrum converts the controls of your oscilloscope to
those of a spectrum analyzer. Adjust the frequency span, resolution and
center frequency. Apply filtering to your signal and watch the frequency
signature change in real time. A unique peak search labels the spectral
components and presents frequency and level in a table. Touch any line
jump to that peak.
Mixed Signal Oscilloscope Option (MS-250/MS-500)
The Mixed Signal option allows the WavePro 7 Zi to convert to a
mixed signal oscilloscope with up to 36 digital channels. Channels are
sampled at 2 GS/s up to 50 Mpts/Ch. Having up to 36 digital inputs
timesynchronized with four analog channels extends the oscilloscope's
use to provide a total system view.
Jitter and Timing Analysis Package
Specialized timing
parameters measure period, cycle-cycle, half period, width, etc. jitter
on a variety of signals. Use the three views of jitter (statistical,
time, and frequency) to understand root cause and to debug problems.
Histograms provide understanding of statistical distributions. Tracks
provide a means to show time-correlated peaks of jitter, and compare to
other signals. FFTs provide the ability to debug root causes of high
in-circuit jitter.
11:42 AM
Explore SDA 7 Zi-A

While some solutions simply provide problem notifications, the SDA 7 Zi-A is the only oscilloscope that helps you identify the problem and and put your project back on schedule.
SDA 7 Zi-A Serial Data Analyzers - LeCroy Indonesia
Agen Resmi Teledyne LeCroy Indonesia
SDA 7 Zi-A Serial Data Analyzers
SDA 7 Zi-A Serial Data Analyzers are based on the WavePro 7 Zi-A Series oscilloscope and are equipped with double the standard memory to capture more unit intervals in the eye diagram. They include an enhanced high-speed serial pattern trigger that operates on up to 80 bit patterns and at speeds up to 2.7 Gb/s. Whether debugging eye pattern failures, or other compliance test failures, the SDA Series has easily accessible tools that rapidly isolate the source of the problem in your design.Explore SDA 7 Zi-A
SDA 725Zi-A (2.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
SDA 735Zi-A (3.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
SDA 740Zi-A (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
SDA 760Zi-A (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Check up to three models.
Quick Specs
Powerful SDA II Analysis Package
Unleash the power of serial data analysis to understand and characterize
your design, prove compliance, and determine why a device or host fails
compliance.
But how do you determine why a device fails compliance? LeCroy's SDA
II serial data debug software is the most powerful and versatile
solution for finding the root cause of serial data compliance failures.
SDA II provides the confidence you need to ensure proper functionality.While some solutions simply provide problem notifications, the SDA 7 Zi-A is the only oscilloscope that helps you identify the problem and and put your project back on schedule.
Versatile SDA II for Compliance and Debug
For compliance testing, LeCroy's QualiPHY compliance test suite provides
the best available solutions to automate, configure and document
standardized tests. However, when a design fails a compliance test, the
engineer needs an advanced set of tools to identify and solve those
problems. The LeCroy SDA 7 Zi-A includes a debugging toolset that
provides insight into eye and jitter analysis. Armed with this insight,
engineers can confidently drill down and identify the root cause. The
Quick View of the SDA shows the Eye Diagram, TIE Track, Bathtub Curve,
Jitter histogram, NQ-Scale and Jitter Spectrum. No other analyzer
provides simultaneous interaction and real-time changes in all six
measurements. LeCroy's X-Stream II Architecture provides fast updates
and the fastest eye interpretation. The fastest eye building and the
maximum unit intervals per second means the shortest time to reach a
solution.
A high-speed serial trigger enables triggering on up to 2.7 GB/s
serial patterns of up to 80-bits in length, allowing up to two 8b/10b
primitives to be triggered on. Jitter calculations are based on
statistics. With the most advanced long memory performance to 256
Mpts/Ch and X-Stream II enabled responsiveness, eye and jitter analysis
occurs rapidly.
Automated Compliance Testing
QualiPHY compliance test suite provides easy to use step-by-step
instructions for testing compliance on a wide array of serial data
standards. Fast automated test operation, illustrated instructions, and
connection diagrams simplify the process. Complete test reporting is
provided along with a 'stop on fail' feature which begins the debug
process.
Whether debugging eye pattern or other compliance test failures, the
SDA 7 Zi-A Series has the accessible tools. Rapidly isolate the source
of the problem in your design. Advanced usability like 8b/10b decode,
mask violation locator, ISI plot, and equalization are easy to find.
Provide cable characteristics and Cable De-embedding automatically
adjusts for the cable effects. The result—true rise time and amplitudes
in measurements. The SDA uses the same flexible math on math analysis
which is valuable when understanding design behavior in the event of a
compliance failure.
SDA II – Advanced Tools to Isolate and Analyze
Flow Diagram User Interface
Eye and Jitter Analysis in the SDA 7 Zi-A begins with a simple,
interactive flow diagram user interface intuitively guiding the user
through the setup of Eye Measurements, Jitter Measurements, or both at
the same time.
Serial Trigger
The SDA 7 Zi-A Series comes standard with the 80-bit Pattern Trigger
installed. The SDA 760Zi and SDA 740Zi include the High-speed Pattern
Trigger option (up to 2.7 Gb/s), while the SDA 735Zi and SDA 725Zi
pattern triggers up to 1.25 Gb/s. Both pattern triggers provide a
recovered clock and data output on the front of the oscilloscope.
8b/10b Decoding
LeCroy's 8b/10b serial decode option with powerful search capability
enables captured waveforms to be searched for user-defined sequences of
symbols. Multi-lane analysis decodes up to four simultaneously captured
lanes.
Equalization
Equalization removes the effects created in systems that utilize
equalization. Users can view the eye of a waveform as seen by a receiver
that employs equalization.
ISI Plot
The ISI plot displays data dependent jitter contributions to the eye
pattern for the second-to-last bit of a bit length, set from 3 to 10.
This plot measures data dependent jitter without the need for a
repeating bit pattern.
Jitter Spectrum
- The jitter spectrum plot allows viewing of any periodic jitter
- Peak annotation displays the frequencies directly on the spectrum
- The LeCroy spectrum plot allows viewing of DDj removal for maximum understanding
Jitter Trend
- Time domain view of jitter shows transient jitter events often missed by viewing can be missed by viewing the histogram alone
- The jitter trend clearly shows any non-stationary jitter behavior
Histogram & Bathtub
- Display of measured jitter histogram clearly shows any unusual jitter distributions such as bi-modal or non-Gaussian tails. By simply viewing the jitter breakdown (Rj, Dj), the raw data view shows jitter behavior that can be lost
- This unprocessed display gives a high degree of confidence in the accuracy of the jitter breakdown and bathtub curve
Eye Patterns Show Mask Violations to the Bit
- Eye pattern measurement on up to 8 million consecutive bits ensures that even transient jitter and noise events are captured
- Consecutive bit eye pattern analysis allows for the measurement of the wave shapes of individual bits that violate the compliance mask (violation location)
- The fastest UI accumulation and very low measurement jitter (typically 1 ps rms)
Cable De-embedding
Even expensive, high-performance cabling can have an adverse effect on
measurements and steal margin from a design. Cable losses and slow rise
times can lead to intersymbol interference that is induced by the
measurement system but is not present in the design. The cable
de-embedding feature removes these adverse effects leading to more
accurate measurements.
Superior Eye Diagram Analysis
SDA II Advanced Debug for Eye and Jitter Analysis
LeCroy''s X-Stream II technology enables unprecedented speed in eye
diagram creation. With a 15.3" high definition display and flexible
landscape views, the SDA 7 Zi-A provides more insight into eyes than
ever before. New features, such as IsoBER, add insight to the
traditionally non-quantitative view of eye openings.
In addition, properly distinguishing between the random and
deterministic jitter in a serial data signal is a crucial part of being
able to reduce the overall jitter. For example, properly identifying
frequencies at which periodic jitter is present is typically a common
part of determining that jitter source. The SDA 7 Zi-A is the only
analyzer that fully integrates jitter measurements into the oscilloscope
software leading to greater confidence in jitter measurements.
Dual-Eye View Mode
Viewing the Transition and Non-Transition eye diagrams allows for
analysis of de-emphasis in serial data waveforms. In addition, Dual-Eye
Gated enables the creation of two separate eyes based on a separate
signal input (i.e. Read/Write).
Mask Violation Locator
Mask failures are identified by contrasting color spots which appear
anywhere the data intersects the mask template. Users can call up the
actual stored bit stream waveform at the point in time of the initial
failure. The actual bit sequence is also identified, pointing out any
ISI problems. Instantly jump to the next violation, or any other within
the stored pattern.
IsoBER
Mask testing is not always the best way to determine if the signal is
going to meet Bit Error Rate requirements because it lacks quantitative
analysis of vertical noise and jitter. LeCroy's unique IsoBER analysis
tool provides this quantitative analysis by extrapolating the eye
diagram data and displaying the lines of BER directly on the eye. This
helps to quickly determine the minimum eye opening and also is
instrumental in detecting cross-talk by analyzing the vertical eye
closure. These measurements are not possible with standard eye diagram
techniques.
More confidence in jitter Breakdown
Simplify Jitter Decomposition
The sources of jitter can be categorized as Deterministic or Random,
which is an important distinction in calculating the Total Jitter (TJ)
of a signal. There are cases where cross talk, or other types of
deterministic jitter, can masquerade as random jitter and cause
incorrect calculations.
LeCroy's integrated SDA II jitter analysis offers two decomposition
algorithms to account for these situations, giving the user confidence
that all jitter components are accurately recognized and processed
correctly. The jitter decomposition calculates both methods
simultaneously and alerts the user only when there is a deviation
between the results, giving assurance that the correct jitter values are
displayed.
Intuitive Jitter Breakdown Displays
LeCroy's SDA II Serial Data Analysis provides intuitive graphical views
of jitter decomposition to quicken insight to the root cause.
To understand deterministic jitter values and their sources, SDA II provides the following tools:
- Periodic Jitter Spectrum identifies the sources contributing the highest values of Pj.
- ISI Plot isolates bit patterns that contribute the most Intersymbol Interference (ISI)
- DDJ Histogram provides a greater understanding of the distributionof Data Dependent Jitter (DDJ)
Setup Warning Indicators
Green / Yellow / Red setup warning indicators alert the user if there is
something that requires their attention. For example, if the user's
input signal is a clock and they have not selected clock as their signal
type, a yellow indicator will be displayed informing the user that they
have an inconsistency in the setup that may require their attention.
11:41 AM
Explore DDA 7 Zi-A
The X-Stream II architecture enables fast and accurate measurements and analysis of disk drive signals. Memory can be extended to 128 Mpts/Ch (256 Mpts/Ch on 2 Ch) using Option L. Both the DDA 760Zi and DDA 735Zi offer the convenience of selectable 50 Ω or 1 MΩ inputs. The standard 20 Mpts of waveform memory and 40 GS/s capture on two channels, means multiple drive sectors can be acquired at once.
The DDA 7 Zi-A features:
DDA 7 Zi-A Disk Drive Analyzers - LeCroy Indonesia
Teledyne LeCroy Indonesia
DDA 7 Zi-A Disk Drive Analyzers
Based on the WavePro 7 Zi-A Series models, the DDA 7 Zi-A Series Disk Drive Analyzers are available in 3.5 and 6 GHz models and come equipped with 20 Mpts/ch acquisition memory. Dedicated disk drive measurements, trigger and zooming for failure analysis, and serial data measurement capability with a Disk Drive Analyzer user interface are also standard to address high capacity disk drive designs. Operate in either DDA or SDA mode to analyze the serial data links or the physical media behavior on a hard drive.Explore DDA 7 Zi-A
Check up to three models.
A Total Solution for Disk Drive Analysis
Maximum Performance
LeCroy Disk Drive Analyzers (DDA) assist data storage design engineers
by integrating tools that improve the time to market of new products and
accelerate understanding and failure analysis on existing drives.
LeCroy continues that tradition with the DDA 7 Zi-A Series equipped with
its powerful Disk Drive Analysis toolset. Capture, view, and analyze
the wave shape of high-speed, complex drive signals with speed and
integrity.
Data Storage applications are memory intensive as capturing multiple
sectors or a complete track of data can be important in troubleshooting a
design or characterizing media.The X-Stream II architecture enables fast and accurate measurements and analysis of disk drive signals. Memory can be extended to 128 Mpts/Ch (256 Mpts/Ch on 2 Ch) using Option L. Both the DDA 760Zi and DDA 735Zi offer the convenience of selectable 50 Ω or 1 MΩ inputs. The standard 20 Mpts of waveform memory and 40 GS/s capture on two channels, means multiple drive sectors can be acquired at once.
Long Memory and Flexibility in Finding Problems
Acquire a head signal up to 6 GHz, and then QuickZoom it from the front
panel. The DDA copies and expands the drive signal automatically. Simply
scroll horizontally and vertically to examine any sector. Multiple
zooms let you view up to eight separate areas of the head signal; each
zoom comes in a distinct color. Disk drive parameters let you
characterize the pulse width variation or signal-to-noise ratio across a
region. Failure Analysis engineers can store and recall golden
waveforms and panel setups to compare problem drives with the known good
drives. Analog-to-digital converters running at speeds up to 40 GS/s
ensure the right sensitivity to measure today's high-speed read
channels. In every DDA, you can run your customer-developed scripts to
view the captured signal with the filters matched to your channel and
media. Custom user scripts can be created in MATLAB, Visual Basic, Excel
or other formats.
Exceptional Trigger and Sequence Performance
The DDA's disk triggers allow you to set up a series of events in the
signal that then cause a trigger. For example, qualify the signal on the
index signal and then capture all the sectors of information on the
track. As memory is increased in the DDA, more sectors can be captured,
with up to 50 picosecond/sample time resolution. Up to 15,000 sectors of
data can be gathered with the DDA 7 Zi-A analyzers. An optional
capability, Streaming Sequence, uses the X-Stream II and the fast
hardware architecture of the DDA to streamup to 300,000 segments of data
to memory; all taken at a high trigger rate.
Natural Graphical Interface
One press on the DDA menu takes you directly to the Disk Drive Analyzer
features. The familiar controls on the front panel, coupled with a
natural, context-sensitive graphical user-interface, react quickly to
your commands. Functionality is exactly where you expect it to be.
The DDA 7 Zi-A provides one button access to all the tools needed to accurately debug and analyze disk drive operation.The DDA 7 Zi-A features:
- 31 custom parameters
- 4 specific drive trigger
- Sector
- Servo Gate
- PES trigger
- Read Gate Trigger
- Advanced drive analysis tools
- Head Filter Equalizer emulation
- Channel Emulation
- SAM Histograms
- Plot of SAM values
- PES runout analysis
- Analog Compare
11:39 AM
Explore HRO 12-bit Oscilloscopes

Check up to three models.
High Resolution Oscilloscopes HRO 64Zi and HRO 66Zi, 400MHz and 600MHz models
The world's clearest and lowest-noise Oscilloscopes are the new HRO
models from LeCroy. LeCroy's High Resolution Oscilloscopes combine true
12-bit ADC's and newly designed low-noise front ends to deliver
unmatched signal fidelity. From the crisp, ultra-thin traces to the
blazing update speed and responsiveness, LeCroy HRO models provide a
shocking contrast to traditional 8-bit oscilloscopes.
A New Way to Navigate and View
The WavePilot control area provides convenient control of Cursors,
Decode, WaveScan, History, LabNotebook, and Spectrum by their respective
function buttons on the front panel.
The SuperKnob is a joystick-like knob in the center of the WavePilot control area used to easily navigate through tables, zoom and position waveforms, and quickly document and annotate your setups.
Simply slide the button on the left side of the display and rotate upwards 90º. The display will automatically change from landscape to portrait mode. The display will also pivot upwards and downwards to optimize viewing angle.
More Trigger Capability Isolates More Problems More Quickly
A powerful combination of high bandwidth edge and 10 different SMART
triggers, four stage cascade triggering, measurement trigger, and
TriggerScan are all standard and allow you to isolate the problem
quickly and begin focus on the cause. The measurement trigger offers a
powerful option to qualify a trigger event based on a qualified
measurement with great resolution.
Rotating Display
The 12.1" high resolution WXGA wide screen is designed to provide the best view of any signal type on the display.
The widescreen is ideal for a variety of signals where long records are required and zooming or scrolling results in a large block of data.
Rotate the screen 90° degrees to optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequency plots. The screen image will adjust automatically when rotated. Tilt the display up or down in either orientation to minimize reflections or glare.
HRO 12-bit Oscilloscopes - LeCroy Indonesia
Teledyne LeCroy Indonesia
HRO 12-bit Oscilloscopes
The HRO (High Resolution Oscilloscope) features an industry leading 12-bit Analog to Digital Convertor (ADC), deep memory of 256 Mpts/Ch, and superior DC accuracy specifications.Explore HRO 12-bit Oscilloscopes
Check up to three models.
Superior Validation, Debug, Analysis
LeCroy HRO models contain a powerful feature set which includes a
wide range of application packages, advanced triggering to isolate
events, a user interface developed for quick and easy navigation, a wide
range of probing options, and lightning-fast performance.
Excellent Signal Fidelity
The LeCroy HRO family features a pristine signal acquisition
architecture that offers unmatched signal fidelity with low noise. This
performance is augmented by a huge offset and timebase delay adjustment
to allow easy signal and amplifier performance assessment and zooming on
vertical and horizontal signal characteristics.The SuperKnob is a joystick-like knob in the center of the WavePilot control area used to easily navigate through tables, zoom and position waveforms, and quickly document and annotate your setups.
Simply slide the button on the left side of the display and rotate upwards 90º. The display will automatically change from landscape to portrait mode. The display will also pivot upwards and downwards to optimize viewing angle.
The widescreen is ideal for a variety of signals where long records are required and zooming or scrolling results in a large block of data.
Rotate the screen 90° degrees to optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequency plots. The screen image will adjust automatically when rotated. Tilt the display up or down in either orientation to minimize reflections or glare.
11:38 AM
Explore HDO6000 High Definition Oscilloscopes
HDO6000 High Definition Oscilloscopes - LeCroy Indonesia
Teledyne LeCroy Indonesia
HDO6000 High Definition Oscilloscopes
HDO6000 oscilloscopes combine Teledyne LeCroy's HD4096 high definition technology with powerful analysis and debug tools, long memory, in a compact form factor with a 12.1" multi-touch display.Explore HDO6000 High Definition Oscilloscopes
Check up to three models.
Key Features
- 12-bit ADC resolution, up to 15 bits with enhanced resolution
- 350 MHz, 500 MHz and 1 GHz bandwidths
- Long Memory - up to 250 Mpts/Ch
- 12.1" Multi-touch screen display with small footprint
- Spectrum Analyzer Mode standard
- WaveScan - Advanced Search and Find
- History Mode - Waveform Playback
- Power Analysis Software
- JITKIT Clock-Data Jitter Analysis
- Serial Data Trigger and Decode
- LabNotebook Report Generation
- Advanced Trigger Tools including TriggerScan and Software Assisted Trigger
HD4096 High Definition Technology
HD4096 high definition technology enables oscilloscopes to capture
and display signals of up to 1 GHz with high sample rate and 16 times
more resolution than other oscilloscopes.
Benefits of HD4096 Technology
Waveforms captured and displayed on oscilloscopes with HD4096
technology are cleaner and crisper. Signal details often lost in the
noise are clearly visible and easy to distinguish HD4096 enables
oscilloscopes to deliver unmatched measurement precision for improved
debug and analysis.
Touch Screen Simplicity
Easily control channels, trigger, math and measurements with the large multi-touch display and intuitive interface.
Comprehensive Analysis Tools
Comprehensive set of waveform math and measurement tools extends the debugging and analysis capability.
History Mode Waveform Playback
Scroll back in time to isolate anomalies and quickly find the source of the problem.
Identify and Isolate Problems Fast
Quickly locate analog or digital waveforms for runts, glitches or other anomolies with WaveScan
Save, Document, Report
Save all results and data with a single button press and create custom reports with LabNotebook
Spectrum Analyzer Interface
View signal details in the frequency domain with a spectrum analyzer style user interface
Complete Set of Applications
Complete set of solutions available for embedded, digital, power and automotive designs extends analysis
Serial Bus Trigger and Decode
View decoded protocol information on top of physical layer waveforms and trigger on protocol specific messages
Simple Power Measurements
Measure and analyze operating characteristics of power conversion devices and circuits
11:36 AM
Explore WaveRunner 6 Zi Oscilloscopes

The WavePilot control area provides convenient control of Cursors, Decode, WaveScan, History, LabNotebook, and Spectrum by their respective function buttons on the front panel.
The SuperKnob is a joystick-like knob in the center of the WavePilot control area used to easily navigate through tables, zoom and position waveforms, and quickly document and annotate your setups.
Simply slide the button on the left side of the display and rotate upwards 90º. The display will automatically change from landscape to portrait mode. The display will also pivot upwards and downwards to optimize viewing angle.
A powerful combination of high bandwidth edge and 10 different SMART triggers, four stage cascade triggering, measurement trigger, and TriggerScan are all standard and allow you to isolate the problem quickly and begin focus on the cause. The measurement trigger offers a powerful option to qualify a trigger event based on a qualified measurement with great resolution. A high-speed serial trigger enables triggering on up to 3 Gb/s serial patterns of up to 80-bits in length. A full range of serial triggers (I2C, SPI, UART, RS-232, Audio (I2S, LJ, RJ, TDM), CAN, LIN, FlexRay, MIL-STD-1553, SATA, PCIe, 8b/10b, USB2 and many others) are also available.
The 12.1" high resolution WXGA wide screen is designed to provide the best view of any signal type on the display.
The widescreen is ideal for a variety of signals where long records are required and zooming or scrolling results in a large block of data.
Rotate the screen 90° degrees to optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequency plots. The screen image will adjust automatically when rotated. Tilt the display up or down in either orientation to minimize reflections or glare.
WaveRunner 6 Zi Oscilloscopes - LeCroy Indonesia
Agen Resmi Teledyne LeCroy Indonesia
WaveRunner 6 Zi Oscilloscopes
The WaveRunner 6 Zi oscilloscope is the most versatile scope in the 400 MHz to 4 GHz class. The performance is unmatched, offering deep memory, 40 GS/s sample rate, low noise and fast operation.Explore WaveRunner 6 Zi Oscilloscopes
WaveRunner 640Zi (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
WaveRunner 625Zi (2.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
WaveRunner 620Zi (2 GHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Quick Specs
WaveRunner 610Zi (1 GHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Quick Specs
WaveRunner 606Zi (600 MHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Quick Specs
WaveRunner 604Zi (400 MHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Check up to three models.
Quick Specs
Superior Validation, Debug, Analysis
The WaveRunner 6 Zi defines superiority in a test instrument. The
powerful feature set includes a wide range of application packages,
advanced triggering to isolate events, a user interface developed for
quick and easy navigation, a wide range of probing options, and
lightning-fast performance.
WaveRunner 6 Zi Oscilloscope Videos
Most Comprehensive Serial Data Analysis
WaveRunner 6 Zi offers the most tools for serial data analysis. With
over 17 trigger, decode, and compliance solutions, WaveRunner 6 Zi can
address problems with unique, powerful views and automated tools. The
unique measurement toolset, ProtoSync, combines the oscilloscope view
with a simultaneous view of data link layer decodes on the same
instrument.
Excellent Signal Fidelity
The WaveRunner 6 Zi oscilloscope family features a pristine signal
path that offers unmatched signal fidelity with low noise. This
performance is augmented by a huge offset and timebase delay adjustment
to allow easy signal and amplifier performance assessment and zooming on
vertical and horizontal signal characteristics.The WavePilot control area provides convenient control of Cursors, Decode, WaveScan, History, LabNotebook, and Spectrum by their respective function buttons on the front panel.
The SuperKnob is a joystick-like knob in the center of the WavePilot control area used to easily navigate through tables, zoom and position waveforms, and quickly document and annotate your setups.
Simply slide the button on the left side of the display and rotate upwards 90º. The display will automatically change from landscape to portrait mode. The display will also pivot upwards and downwards to optimize viewing angle.
A powerful combination of high bandwidth edge and 10 different SMART triggers, four stage cascade triggering, measurement trigger, and TriggerScan are all standard and allow you to isolate the problem quickly and begin focus on the cause. The measurement trigger offers a powerful option to qualify a trigger event based on a qualified measurement with great resolution. A high-speed serial trigger enables triggering on up to 3 Gb/s serial patterns of up to 80-bits in length. A full range of serial triggers (I2C, SPI, UART, RS-232, Audio (I2S, LJ, RJ, TDM), CAN, LIN, FlexRay, MIL-STD-1553, SATA, PCIe, 8b/10b, USB2 and many others) are also available.
The 12.1" high resolution WXGA wide screen is designed to provide the best view of any signal type on the display.
The widescreen is ideal for a variety of signals where long records are required and zooming or scrolling results in a large block of data.
Rotate the screen 90° degrees to optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequency plots. The screen image will adjust automatically when rotated. Tilt the display up or down in either orientation to minimize reflections or glare.
11:35 AM
Explore WaveRunner Xi-A

The LeCroy WaveRunner Xi-A is the most powerful and capable scope available in its class. Basic system validation using advanced triggers, fast viewing modes, measurement parameters, or serial decodes is simple and easy. Advanced debug, multi-domain analysis, and waveshape analysis are possible with tools unique to WaveRunner Xi-A. Optional application packages help you make sense of well-defined problems.
Trigger on I2C, SPI, UART, RS-232, AudioBus (I2S, LJ, RJ, TDM), LIN, CAN, or FlexRay or MIL-STD-1553 serial data patterns. Intuitively decode values on the oscilloscope grid.
An
extensive collection of SMART, Serial, and Digital (MS Series) triggers
enables users to quickly and easily isolate events of interest (some
optional).
Use
the high sampling rate and WaveStream fast viewing mode to characterize
signal shape, rise time, overshoot, etc., and verify the presence or
absence of high-speed transients.
Sequence
Mode allows you to partition your acquisition memory into segments and
capture specific events over long periods of time. Then, view and
analyze each segment individually.
Search
and Analysis WaveScan provides the ability to locate unusual events in a
single capture, or scan for an event in many acquisitions over a long
period of time using more than 20 different search/scan modes. Use
ScanHisto or ScanOverlay to display intuitive scanned results.
Use a variety of application packages to provide detailed, fast solutions for specific problems.
Amplify
your understanding with multidomain analysis of your signals. Convert
signal information into Statistical domain (Histogram), Spectral domain
(long memory FFTs), Jitter, Modulation, or other Measurement Parameter
domains (Tracks of measurement parameters). (Some capability is
optional.)
LeCroy
math, measure, and analysis tools are tightly integrated with basic
scope operations. It's easy to link capabilities and expand
understanding. Free yourself from constraints!
WaveRunner Xi-A / MXi-A Oscilloscopes - LeCroy Indonesia
Agen Resmi Teledyne LeCroy Indonesia
WaveRunner Xi-A / MXi-A Oscilloscopes
The LeCroy WaveRunner Xi-A is the most powerful and capable scope available in its class. Basic system validation using advanced triggers, fast viewing modes, measurement parameters, or serial decodes is simple and easy. Advanced debug, multi-domain analysis, and waveshape analysis are possible with tools unique to WaveRunner Xi-A. Optional application packages help you make sense of well-defined problems.Explore WaveRunner Xi-A
WaveRunner 204MXi-A (2 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Limited Availability
Limited Availability
Quick Specs
WaveRunner 204Xi-A (2 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Limited Availability
Limited Availability
Quick Specs
WaveRunner 104MXi-A (1 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
WaveRunner 104Xi-A (1 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
WaveRunner 64MXI-A (600 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
WaveRunner 64Xi-A (600 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
WaveRunner 62Xi-A (600 MHz Bandwidth, 2 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
WaveRunner 44MXi-A (400 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
WaveRunner44Xi-A (400 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Check up to three models.
Quick Specs
The LeCroy WaveRunner Xi-A is the most powerful and capable scope available in its class. Basic system validation using advanced triggers, fast viewing modes, measurement parameters, or serial decodes is simple and easy. Advanced debug, multi-domain analysis, and waveshape analysis are possible with tools unique to WaveRunner Xi-A. Optional application packages help you make sense of well-defined problems.
Enhanced Understanding of Serial Data Signals
Powerful Triggers Isolate Events
WaveStream™ Fast Viewing Mode
Advanced Acquisition Modes
WaveScan™ Advanced
Completely Customizable
Quickly create your own measurement parameters or math functions using Excel, MATLAB®, or VBScripts (some capability optional).
Advanced Application Packages
Fast Long Memory with Front Panel Zoom Controls
WaveRunner Xi-A's long memory is optimized for calculation of more
information 10–100x faster than other oscilloscopes, while enabling easy
access to simple zooming and positioning from the front panel.
Extensive Math and Measurement Capability
More standard and optional measurements and more powerful math
capability are provided with results returned faster than in other
oscilloscopes.
Beyond Time Domain Analysis
Integrated Tool Sets
Complete Probing Solutions
A wide variety of active FET probes, current probes, differential
probes, HV probes, etc. with complete tip and ground accessories make it
easy to probe your signals.
Mixed Signal Oscilloscope Option
The MS Series can capture digital signals with speeds up to 500 MHz.
View up to 36 digital channels with up to 50 Mpts/Ch memory and analyze
analog and digital events together.
Power/Amplifier Measurements
Excellent overdrive recovery and signal integrity make WaveRunner
Xi-A ideal for high-voltage switching loss, conduction loss, ripple,
switching power supply, and other amplifier measurements. Use with
LeCroy Differential Amplifiers for highperformance 100,000:1 Common Mode
Rejection Ratio.
Timing Characterization
Extensive triggers allow fast event isolation. Measure timing
statistically and view behavior graphically using histograms. Gain real
understanding of root cause.
Slow/High-speed Signal Mix
Long memory, HFREJ trigger coupling, built-in noise filtering, etc.
enable fast understanding of signal behavior in circuits with a mix of
slow-speed (sensor, actuator, power supply, mechanical) and high-speed
signals.