Kyoritsu Earth Testers

Latest Post
Showing posts with label LeCroy Indonesia. Show all posts
Showing posts with label LeCroy Indonesia. Show all posts

WaveExpert Sampling Oscilloscopes - LeCroy Indonesia

Written By Anonymous on January 16, 2013 | 11:54 AM

Agen Resmi Teledyne LeCroy Indonesia

WaveExpert Sampling Oscilloscopes

The ideal signal integrity analysis solution for high-speed links. Measurement complexity and the emergence of receiver equalization which allows high-speed serial data links to operate error-free even when the signal is severely distorted requires WaveExpert's high bandwidth and detailed analysis capability.
Explore WaveExpert 

WaveExpert 100H   ( 100 GHz Bandwidth, Max Sample Rate )
Check up to three models.




Ultra-High Bandwidth Signal Analysis
Eye pattern analysis is the primary method of signal integrity testing for optical signals and the WaveExpert performs this analysis over 20 times faster than conventional sampling oscilloscopes.
A maximum bandwidth of 100 GHz along with a 230 fsrms noise floor enables measurements on the fastest optical signals.
Highly Accurate Jitter Analysis
The low jitter noise floor of the HCIS timebase along with LeCroy’s innovative Q-Scale jitter analysis provides over 3 times the accuracy over conventional sampling scope methods for all jitter types.
Up to 20 GHz TDR with Full S-parameter Measurements
The standard TDR analysis package included with the WaveExpert 100H offers full reference plane calibration and 1 and 2 port differential S-parameter measurement fully integrated into the instrument interface.
Eye Doctor™ Offers Virtual Probing and Equalized Signals
The Virtual Probing and equalized receiver emulation features in the Eye Doctor package provide full end-to-end signal integrity analysis of serial data systems employing equalization.

LabMaster 10 Zi Oscilloscopes - LeCroy Indonesia

Agen Resmi Teledyne LeCroy Indonesia

LabMaster 10 Zi Oscilloscopes

The LabMaster 10 Zi is the world's highest bandwidth real-time oscilloscope - 65 GHz at 160 GS/s. LabMaster 10 Zi is also modular - it breaks channel count barriers and provides more "bandwidth density". The modular design provides the simplest upgrade path in bandwidth and channel count, with one acquisition module providing four channels at 36 GHz or two channels at 65 GHz, with capability for up to 20 acquisition modules .
Explore LabMaster 10 Zi 

LabMaster 10 Zi 25 GHz Systems  (25 GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
 
LabMaster 10 Zi 30 GHz Systems  (30 GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
 
LabMaster 10 Zi 36 GHz Systems  (36 GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
 
LabMaster 10 Zi 50 GHz Systems  (50 GHz Bandwidth, Up to 40 Input Channels, 160 GS/s Max Sample Rate; 36 GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
 
LabMaster 10 Zi 60 GHz Systems  (60 GHz Bandwidth, Up to 40 Input Channels, 160 GS/s Max Sample Rate; 36 GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
 
LabMaster 10 Zi 65 GHz Systems  (65 GHz Bandwidth, Up to 40 Input Channels, 160 GS/s Max Sample Rate; 36 GHz Bandwidth, Up to 80 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
 
Check up to three models.
The Ultimate in High Bandwidth Performance
  • Up to 65 GHz
  • Up to 80 Channels @ 36 GHz
  • Up to 160 GS/s
  • Up to 1024 Mpts/Ch
LabMaster 10 Zi modular oscilloscope systems completely re-define oscilloscope performance and capabilities.
  • Multi-channel operation at the highest bandwidths
    • 40 channels @ 65 or 50 GHz
    • 80 channels @ 36, 30, or 25 GHz
  • Bandwidth and channel upgrade flexibility
  • ChannelSync for precise synchronization of all acquisition modules
  • Server-class CPU (33.6 GHz effective clock rate, up to 192 GB RAM)
  • Ultra-low jitter noise floor (100 fs rms) and ultra-high time base stability.
  • 5.2 ps (20-80%) rise time
  • 14.1 Gb/s hardware serial trigger (28 Gb/s in development)
LabMaster 10 Zi leverages the unique LabMaster ChannelSync architecture with next-generation 8HP SiGe chipsets to produce the world’s highest bandwidth, four channel oscilloscope – 36 GHz. When combined with LeCroy’s patented DBI technology, bandwidth nearly doubles to 65 GHz, with sample rates of 160 GS/s. Truly extraordinary.
The LabMaster class of oscilloscopes are fundamentally better – they are modular, inherently upgradeable, and infinitely flexible while retaining all of the simplicity of operation that you expect from a conventional oscilloscope. LabMaster 10 Zi oscilloscopes can be configured for massive numbers of channels at up to 65 GHz – truly eliminating your technology and test barriers.
LeCroy’s ChannelSync architecture ensures precise synchronization of all acquisition modules. ChannelSyn ensures precise synchronization of all channels in all acquisition modules by using a single-distributed 10 GHz clock and a single trigger circuit. External clocking is not required, and trigger jitter from multiple trigger circuits is non-existent. Jitter between all channels is an ultra-low <275 fsrms,. Synchronization performance is identical to that provided with a single, standard oscilloscope package, and all captured waveforms and analysis appears on one oscilloscope display.
LabMaster 10 Zi is perfect for developed and emerging 10-12 Gb/s technologies, such as 40/100 GBASE-R Ethernet and SAS12, benefit from 80 GS/s on four (or more) channels at up to 36 GHz. Ultra-high speed technologies, such as CEI-25/28, CEI-56, and optical coherent modulation communication systems (DP-QPSK, 16-QAM, MIMO) benefit from the world’s fastest real-time bandwidth (65 GHz) and four or more channels. LeCroy's SDAIII-CompleteLinQ Serial Data and Crosstalk Analysis software provides even more capability for simulataneous multi-lane eye, jitter, vertical noise and crosstalk analysis.

LabMaster 9 Zi-A Oscilloscopes - LeCroy Indonesia

Agen Resmi Teledyne LeCroy Indonesia

LabMaster 9 Zi-A Oscilloscopes

The LabMaster 9 Zi-A builds on the acquisition and analysis excellence of the LeCroy WaveMaster 8 Zi-A oscilloscopes, but uses a modular design to provide massive numbers of channels (up to 80 channels at up to 20 GHz), up to five channels at 45 GHz, or something in between. Maximum sample rate is 120 GS/s with maximum analysis memory of 768 Mpts/Ch. LabMaster 9 Zi-A oscilloscopes have pioneered next-generation research and development in optical transmission, high speed SERDES, and multi-lane serial data transmissions.
Explore LabMaster 9 Zi-A 

LabMaster 9 Zi-A 13 GHz Systems  (13 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
LabMaster 9 Zi-A 16 GHz Systems  (16 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
LabMaster 9 Zi-A 20 GHz Systems  (20 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
LabMaster 9 Zi-A 30 GHz Systems  (30 GHz Bandwidth, Up to 40 Input Channels, 80 GS/s Max Sample Rate, 20 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max )
Quick Specs
 
LabMaster 9 Zi-A 36 GHz Systems  (36 GHz Bandwidth, Up to 40 Input Channels, 80 GS/s Max Sample Rate, 20 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max )
Quick Specs
 
LabMaster 9 Zi-A 45 GHz Systems  (45 GHz Bandwidth, Up to 20 Input Channels, 120 GS/s Max Sample Rate; 30 GHz Bandwidth, Up to 40 Input Channels, 80 GS/s Max Sample Rate, 20 GHz Bandwidth, Up to 80 Input Channels, 40 GS/s Max )
Quick Specs
 
Check up to three models.
The Ultimate in Performance
  • Up to 45 GHz
  • Up to 80 Channels @ 20 GHz
  • Up to 120 GS/s
  • Up to 768 Mpts/Ch
LabMaster 9 Zi-A modular oscilloscope systems completely re-define oscilloscope performance and capabilities.
  • Multi-channel operation at the highest bandwidths
    • 20 channels @ 45 GHz
    • 40 channels @ 36 GHz
    • 80 channels @ 20, 16, or 13 GHz
  • Bandwidth and channel upgrade flexibility
  • ChannelSync for precise synchronization of all acquisition modules
  • Server-class CPU (33.6 GHz effective clock rate, up to 192 GB RAM)
  • Ultra-low jitter noise floor (125 fs rms) and ultra-high time base stability.
LabMaster 9 Zi-A provides more of everything, and it's modular design provides the simplest upgrade path in bandwidth and channel count. ChannelSync ensures precise synchronization of all channels in all acquisition modules using a single-distributed 10 GHz clock and a single trigger circuit. The result is the highest timebase accuracy and an ultra-low 275 fs jitter between all channels, identical to that provided with a single, standard oscilloscope package.
Upgrade flexibility is designed in—start with a minimum configuration and add channels over time by simply adding additional acquisition modules, upgrade bandwidth on existing modules, or mix and match bandwidths in one system. A server-class CPU packs additional processing power for the immense amounts of data made possible by LabMaster 9 Zi-A.
LabMaster enables the leading-edge technologies that provide enhanced high speed data transfer and communication—such as 28 – 32 Gb/s SERDES, multi-lane serial data (40/100 GbE, PCIe Gen3), DDR, and optical coherent modulation communications. It's also ideal for defense and aerospace applications where high channel count and high bandwidth are both required.

WaveMaster 8 Zi-A Oscilloscopes - LeCroy Indonesia

Agen Resmi Teledyne LeCroy Indonesia

WaveMaster 8 Zi-A Oscilloscopes


World's Highest Bandwidth Real-time Oscilloscope with Superior Performance
WaveMaster 8 Zi-A combines the highest bandwidth (45 GHz) and sample rate (120 GS/s) with superior signal fidelity performance and 20 GHz on all four input channels. Models are available from 4 to 45 GHz with complete bandwidth upgradability throughout the range. The X-Stream II architecture maximizes speed in all aspects and provides for full analysis on maximum record lengths using LeCroy's flexible and deep analysis toolbox. Explore WaveMaster 8 Zi-A 

WaveMaster 804Zi-A  (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 806Zi-A  (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 808Zi-A  (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 813Zi-A  (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 816Zi-A  (16 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 820Zi-A  (20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 825Zi-A  (25 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 830Zi-A  (30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
WaveMaster 845Zi-A  (45 GHz Bandwidth, 1 Input Channel, 120 GS/s Max Sample Rate; 30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
Check up to three models.
45 GHz Real-Time Bandwidth
LeCroy has again broken bandwidth barriers by utilizing widely adopted and proven SiGe processes, custom 2nd generation ASIC designs, and 6th generation Digital Bandwidth Interleave (DBI) technology to achieve unprecedented real-time oscilloscope performance:
  • 45 GHz
  • 120 GS/s
  • 768 Mpts/Ch Analysis Memory
20 GHz/4ch Model
Four channel performance at 20 GHz is pristine with exceptional rise time, overshoot, total and random jitter noise floor, and electrical noise performance.
LeCroy — The Analysis Memory Leader
LeCroy has found a way to make long acquisition memory seamless and pain free to use. The WaveMaster 8 Zi-A Series' proprietary X-Stream II architecture supports capturing, zooming, measuring and analyzing multiple waveforms at up to 768 Mpts deep. WaveMaster 8 Zi-A's proprietary architecture design is augmented with an Intel® Core™ 2 Quad processor (12 GHz effective clock rate), high-speed serial data buses, Windows 7 64-bit OS and 8 GB of RAM. What you experience is processing speed 10-100x faster compared to other oscilloscopes in this class.
Highest Stability Timebase and Lowest Jitter Noise Floor
An exceptionally accurate and stable time base is incorporated for the best possible jitter measurement accuracy jitter noise floor is as low as 125 fsrms. LeCroy provides highly stable measurements at full (768 Mpts) record lengths, simplifying debug of low frequency events.
Freedom from Probing Limitations
High bandwidth differential probes (up to 25 GHz), single-ended active probes, current probes, high-voltage, and mixed signals all connect to the WaveMaster 8 Zi-A oscilloscope and give you a total system view. All WaveMaster 8 Zi-A oscilloscopes contain selectable 50 Ohm and 1 MOhm input capability and can be used with any LeCroy probe - passive or active - without requiring external adapters or power supplies.

SDA 8 Zi-A Serial Data Analyzers - LeCroy Indonesia

Agen Resmi Teledyne LeCroy Indonesia

SDA 8 Zi-A Serial Data Analyzers

SDA 8 Zi-A Serial Data Analyzers combine the highest bandwidth (45 GHz) and sample rate (120 GS/s) with superior performance at 20 GHz on all four input channels. Models are available from 4 to 45 GHz with complete bandwidth upgradability throughout the range. SDA 8 Zi-A models combine all the attributes of WaveMaster 8 Zi-A with additional capabilities specifically suited for serial data testing.
Explore SDA 8 Zi-A 

SDA 804Zi-A  (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
SDA 806Zi-A  (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
SDA 808Zi-A  (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
SDA 813Zi-A  (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
SDA 816Zi-A  (16 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
SDA 820Zi-A  (20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
SDA 825Zi-A  (25 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
SDA 830Zi-A  (30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
SDA 845Zi-A  (45 GHz Bandwidth, 1 Input Channel, 120 GS/s Max Sample Rate; 30 GHz Bandwidth, 2 Input Channels, 80 GS/s Max Sample Rate; 20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
Check up to three models.
45 GHz Real-Time Bandwidth
LeCroy has again broken bandwidth barriers by utilizing widely adopted and proven SiGe processes, custom 2nd generation ASIC designs, and 6th generation Digital Bandwidth Interleave (DBI) technology to achieve unprecedented real-time oscilloscope performance:
  • 45 GHz
  • 120 GS/s
  • 768 Mpts/Ch Analysis Memory
20 GHz/4ch Model
Four channel performance at 20 GHz is pristine with exceptional rise time, overshoot, total and random jitter noise floor, and electrical noise performance. SDAII Serial Data Analysis Software LeCroy's SDAII software is optimized for fast eye diagram creation on long records, and deep insight of jitter pathologies with more parameters and analysis views to help you understand the root cause of high jitter.
Additional Capability Standard
SDA 8 Zi-A models provide additional capability standard that costs extra in WaveMaster 8 Zi-A models, such as:
  • 32 Mpts/ch memory
  • SDAII software
  • JTA2 software
  • SDM and ET-PMT software
  • 8b10b decode
  • High speed serial trigger
LeCroy—The Analysis Memory Leader
LeCroy has found a way to make long acquisition memory seamless and pain free to use. The SDA 8 Zi-A Series' proprietary X-Stream II architecture supports capturing, zooming, measuring and analyzing multiple waveforms at up to 768 Mpts deep. SDA 8 Zi-A's proprietary architecture design is augmented with an Intel® Core™ 2 Quad processor (12 GHz effective clock rate), high-speed serial data buses, Windows 7 64-bit OS and 8 GB of RAM. What you experience is processing speed 10–100x faster compared to other oscilloscopes in this class.
Highest Stability Timebase and Lowest Jitter Noise Floor
An exceptionally accurate and stable time base is incorporated for the best possible jitter measurement accuracy—jitter noise floor is as low as 125 fsrms. LeCroy provides highly stable measurements at full (768 Mpts) record lengths, simplifying debug of low frequency events.
Freedom from Probing Limitations
High bandwidth differential probes (up to 25 GHz), single-ended active probes, current probes, high-voltage, and mixed signals all connect to the SDA 8 Zi-A serial data analyzers and give you a total system view. All SDA 8 Zi-A serial data analyzers contain selectable 50 Ohm and 1 MOhm input capability and can be used with any LeCroy probe—passive or active—without requiring external adapters or power supplies.

DDA 8 Zi-A Disk Drive Analyzers - LeCroy Indonesia

Agen Resmi Teledyne LeCroy Indonesia

DDA 8 Zi-A Disk Drive Analyzers

DDA 8 Zi-A models combine all the attributes of WaveMaster 8 Zi-A with additional capabilities specifically suited for disk drive and serial data testing.
Explore DDA 8 Zi-A 

DDA 808Zi-A  (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
DDA 820Zi-A  (20 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Quick Specs
 
DDA 830Zi-A  (30 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
 
Check up to three models.

20 GHz/4ch Model
Four channel performance at 20 GHz is pristine with exceptional rise time, overshoot, total and random jitter noise floor, and electrical noise performance.
SDAII Serial Data Analysis Software
LeCroy's SDAII software is optimized for fast eye diagram creation on long records, and deep insight of jitter pathologies with more parameters and analysis views to help you understand the root cause of high jitter.
DDAII Disk Drive Analysis Software
LeCroy's DDAII software is specifically suited for disk drive analysis and is included standard in every DDA 8 Zi-A model.
Additional Capability Standard
DDA 8 Zi-A models provide additional capability standard that costs extra in WaveMaster 8 Zi-A models, such as:
  • 32 Mpts/ch memory
  • SDAII software
  • JTA2 software
  • SDM and ET-PMT software
  • 8b10b decode
LeCroy—The Analysis Memory Leader
LeCroy has found a way to make long acquisition memory seamless and pain free to use. The DDA 8 Zi-A Series' proprietary X-Stream II architecture supports capturing, zooming, measuring and analyzing multiple waveforms at up to 512 Mpts deep. DDA 8 Zi-A's proprietary architecture design is augmented with an Intel® Core™ 2 Quad processor (12 GHz effective clock rate), high-speed serial data buses, Windows 7 64-bit OS and 8 GB of RAM. What you experience is processing speed 10–100x faster compared to other oscilloscopes in this class.
Highest Stability Timebase and Lowest Jitter Noise Floor
An exceptionally accurate and stable time base is incorporated for the best possible jitter measurement accuracy—jitter noise floor is as low as 140 fsrms. LeCroy provides highly stable measurements at full (512 Mpts) record lengths, simplifying debug of low frequency events.
Freedom from Probing Limitations
High bandwidth differential probes (up to 25 GHz), single-ended active probes, current probes, high-voltage, and mixed signals all connect to the WaveMaster 8 Zi-A oscilloscope and give you a total system view. All WaveMaster 8 Zi-A oscilloscopes contain selectable 50 Ohm and 1 MOhm input capability and can be used with any LeCroy probe—passive or active—without requiring external adapters or power supplies.

WavePro 7 Zi-A Oscilloscopes - LeCroy Indonesia

Agen Resmi Teledyne LeCroy Indonesia

WavePro 7 Zi-A Oscilloscopes

Combining signal fidelity with an architecture that maximizes speed in every performance aspect, the new WavePro 7 Zi-A Series presents a totally new oscilloscope experience from 1.5 to 6 GHz bandwidths. Experience 50 Ω and 1 MΩ inputs for every channel and four inputs into high-speed front end amplifiers and analog to digital converters. Experience the new X-Stream II architecture that provides 10 to 20 times faster long memory performance than any other oscilloscope. Combined with LeCroy’s flexible and deep analysis toolbox, the WavePro 7 Zi-A Series gives an unforgettable experience for the debugging, validation, analysis and compliance testing of electronic designs.
Explore WavePro 7 Zi-A 

WavePro 715Zi-A  (1.5 GHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
WavePro 725Zi-A  (2.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
WavePro 735Zi-A  (3.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
WavePro 740Zi-A  (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
WavePro 760Zi-A  (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
Check up to three models.
Freedom from Limitations
WavePro 7 Zi-A excels in the way it offers general purpose utility never before seen in oscilloscopes from 1.5 to 6 GHz. All WavePro 7 Zi-A oscilloscopes contain selectable 50 Ω and 1 MΩ input capability. The 4 and 6 GHz models include both ProBus and ProLink input types which means eight probes can be attached and then multiplexed from the front panel or by remote control. The result— it's easy to hook up a passive probe even on 4 or 6 GHz models—no more frustration and hassle of trying to find a 1 MΩ input adapter. Plus, any existing investment in LeCroy probes, such as current probes, single-ended or differential active probes, or high voltage probes, is fully leveraged. Perfect.
More Triggers Isolate More Problems More Effectively
A powerful combination of high bandwidth Edge and 10 different SMART triggers allow you to isolate the problem quickly and begin to focus on the cause. Most SMART triggers allow triggering on pulse widths or features as small as 200 ps. A high-speed serial trigger enables triggering on up to 2.7 Gb/s serial patterns of up to 80-bits in length. Built-in hardware clock recovery is also included.
TriggerScan™
TriggerScan uses high-speed hardware triggering capability with persistence displays to capture only the signals of interest and provide answers up to 100X faster that other methods. Traditional fast display update modes work best on frequent events occurring on slow edge rates while TriggerScan excels in finding infrequent events on fast edge rates.
WaveScan™ Advanced Search and Analysis Finds Problems that Triggers Won't Find
The best trigger won't find all unusual events—a more powerful capability is sometimes needed. WaveScan provides the ability to locate unusual events in a single capture (i.e., capture and search) or "scan" for an event in many acquisitions over a long period of time. Select from more than 20 search modes (frequency, rise time, runt, duty cycle, etc.), apply a search condition and begin scanning. When an event is found, WaveScan highlights the error on screen and displays a table listing the errors.
Fully Integrated Mixed Signal Oscilloscope (4+36) Option
Add Mixed Signal Oscilloscope (MSO) operation using the MS Series mixed signal options. These convenient add-ons connect to the LeCroy LBUS and quickly and simply provide capability to acquire up to 36 digital lines time-correlated with analog waveforms. No time is wasted in trying to learn how to connect, synchronize or operate a complicated logic analyzer since the MSOs are already completely integrated into the scope operation. In addition to acquiring digital lines, they are also helpful for monitoring low-speed signals, such as serial data clock, data, and chip select signals, thus preserving the analog channels for higher speed requirements.
LeCroy — The Acquisition Memory Leader
LeCroy has found a way to make long acquisition memory seamless and pain free to use. The WavePro 7 Zi Series' proprietary X-Stream II architecture supports capturing, zooming, measuring and analyzing multiple waveforms at 256 Mpts deep. What you experience is performance gains of 10–20X over what is available today. Whether looking at the acquired signal or while analyzing several screens of statistics, tracking a frequency or identifying complex patterns the WavePro 7 Zi is designed to perform.
Instantaneous Responsiveness
The first time you use the Zi oscilloscope you will experience responsiveness that you've never seen before. Acquiring and manipulating the longest record lengths and the most complex WaveShape Analysis are all easily handled at the same time. Whether you use the front panel or choose to make adjustments with a mouse or the touch screen, the system performs.
X-Stream II Architecture
Optimized for Fast Throughput
Designed for long memory operation and responsiveness X-Stream II technology enables high throughput of data—even when the oscilloscope is performing multiple 100 Mpts waveforms. It does so by eliminating the trade-offs between long memory length and quick processing. WavePro 7 Zi's proprietary architecture design is augmented with an Intel® Core™ 2 Quad processor, high-speed serial data buses, a 64-bit OS and up to 8 GB of RAM.
Optimized for Long Memory
By using variable waveform segment lengths to improve the CPU cache memory efficiency the WavePro 7 Zi is designed for the fastest processing of long waveform records. The result—10-20 times faster processing compared to other oscilloscopes.
Optimized for Responsiveness
By dynamically allocating buffers where to maximize memory availability the WavePro 7 Zi Series embodies the fastest front panel responsiveness. Waveform previewing shows interim calculation results while a built in processing abort make front panel control changes instant by stopping the current process and allowing new waveforms to be positioned or zoomed—all without a lengthy recalculation.
Digital Filter Software Package (WPZi-DFP2)
DFP2 lets you implement Finite or Infinite Impulse Response filters to eliminate undesired spectral components, such as noise, and enhances your ability to examine important signal components. You can choose from a standared set of FIR or IIR filters. You can also design your own filters.
Spectrum Analyzer Analysis Package (WPZi-SPECTRUM)
The spectrum converts the controls of your oscilloscope to those of a spectrum analyzer. Adjust the frequency span, resolution and center frequency. Apply filtering to your signal and watch the frequency signature change in real time. A unique peak search labels the spectral components and presents frequency and level in a table. Touch any line jump to that peak.
Mixed Signal Oscilloscope Option (MS-250/MS-500)
The Mixed Signal option allows the WavePro 7 Zi to convert to a mixed signal oscilloscope with up to 36 digital channels. Channels are sampled at 2 GS/s up to 50 Mpts/Ch. Having up to 36 digital inputs timesynchronized with four analog channels extends the oscilloscope's use to provide a total system view.
Jitter and Timing Analysis Package
Specialized timing parameters measure period, cycle-cycle, half period, width, etc. jitter on a variety of signals. Use the three views of jitter (statistical, time, and frequency) to understand root cause and to debug problems. Histograms provide understanding of statistical distributions. Tracks provide a means to show time-correlated peaks of jitter, and compare to other signals. FFTs provide the ability to debug root causes of high in-circuit jitter.

SDA 7 Zi-A Serial Data Analyzers - LeCroy Indonesia

Agen Resmi Teledyne LeCroy Indonesia

SDA 7 Zi-A Serial Data Analyzers

SDA 7 Zi-A Serial Data Analyzers are based on the WavePro 7 Zi-A Series oscilloscope and are equipped with double the standard memory to capture more unit intervals in the eye diagram. They include an enhanced high-speed serial pattern trigger that operates on up to 80 bit patterns and at speeds up to 2.7 Gb/s. Whether debugging eye pattern failures, or other compliance test failures, the SDA Series has easily accessible tools that rapidly isolate the source of the problem in your design.
Explore SDA 7 Zi-A 

SDA 725Zi-A  (2.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
SDA 735Zi-A  (3.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
SDA 740Zi-A  (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
SDA 760Zi-A  (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
Check up to three models.
Powerful SDA II Analysis Package
Unleash the power of serial data analysis to understand and characterize your design, prove compliance, and determine why a device or host fails compliance. But how do you determine why a device fails compliance? LeCroy's SDA II serial data debug software is the most powerful and versatile solution for finding the root cause of serial data compliance failures. SDA II provides the confidence you need to ensure proper functionality.
While some solutions simply provide problem notifications, the SDA 7 Zi-A is the only oscilloscope that helps you identify the problem and and put your project back on schedule.
Versatile SDA II for Compliance and Debug
For compliance testing, LeCroy's QualiPHY compliance test suite provides the best available solutions to automate, configure and document standardized tests. However, when a design fails a compliance test, the engineer needs an advanced set of tools to identify and solve those problems. The LeCroy SDA 7 Zi-A includes a debugging toolset that provides insight into eye and jitter analysis. Armed with this insight, engineers can confidently drill down and identify the root cause. The Quick View of the SDA shows the Eye Diagram, TIE Track, Bathtub Curve, Jitter histogram, NQ-Scale and Jitter Spectrum. No other analyzer provides simultaneous interaction and real-time changes in all six measurements. LeCroy's X-Stream II Architecture provides fast updates and the fastest eye interpretation. The fastest eye building and the maximum unit intervals per second means the shortest time to reach a solution. A high-speed serial trigger enables triggering on up to 2.7 GB/s serial patterns of up to 80-bits in length, allowing up to two 8b/10b primitives to be triggered on. Jitter calculations are based on statistics. With the most advanced long memory performance to 256 Mpts/Ch and X-Stream II enabled responsiveness, eye and jitter analysis occurs rapidly.
Automated Compliance Testing
QualiPHY compliance test suite provides easy to use step-by-step instructions for testing compliance on a wide array of serial data standards. Fast automated test operation, illustrated instructions, and connection diagrams simplify the process. Complete test reporting is provided along with a 'stop on fail' feature which begins the debug process. Whether debugging eye pattern or other compliance test failures, the SDA 7 Zi-A Series has the accessible tools. Rapidly isolate the source of the problem in your design. Advanced usability like 8b/10b decode, mask violation locator, ISI plot, and equalization are easy to find. Provide cable characteristics and Cable De-embedding automatically adjusts for the cable effects. The result—true rise time and amplitudes in measurements. The SDA uses the same flexible math on math analysis which is valuable when understanding design behavior in the event of a compliance failure.
SDA II – Advanced Tools to Isolate and Analyze
Flow Diagram User Interface
Eye and Jitter Analysis in the SDA 7 Zi-A begins with a simple, interactive flow diagram user interface intuitively guiding the user through the setup of Eye Measurements, Jitter Measurements, or both at the same time.
Serial Trigger
The SDA 7 Zi-A Series comes standard with the 80-bit Pattern Trigger installed. The SDA 760Zi and SDA 740Zi include the High-speed Pattern Trigger option (up to 2.7 Gb/s), while the SDA 735Zi and SDA 725Zi pattern triggers up to 1.25 Gb/s. Both pattern triggers provide a recovered clock and data output on the front of the oscilloscope.
8b/10b Decoding
LeCroy's 8b/10b serial decode option with powerful search capability enables captured waveforms to be searched for user-defined sequences of symbols. Multi-lane analysis decodes up to four simultaneously captured lanes.
Equalization
Equalization removes the effects created in systems that utilize equalization. Users can view the eye of a waveform as seen by a receiver that employs equalization.
ISI Plot
The ISI plot displays data dependent jitter contributions to the eye pattern for the second-to-last bit of a bit length, set from 3 to 10. This plot measures data dependent jitter without the need for a repeating bit pattern.
Jitter Spectrum
  • The jitter spectrum plot allows viewing of any periodic jitter
  • Peak annotation displays the frequencies directly on the spectrum
  • The LeCroy spectrum plot allows viewing of DDj removal for maximum understanding
Jitter Trend
  • Time domain view of jitter shows transient jitter events often missed by viewing can be missed by viewing the histogram alone
  • The jitter trend clearly shows any non-stationary jitter behavior
Histogram & Bathtub
  • Display of measured jitter histogram clearly shows any unusual jitter distributions such as bi-modal or non-Gaussian tails. By simply viewing the jitter breakdown (Rj, Dj), the raw data view shows jitter behavior that can be lost
  • This unprocessed display gives a high degree of confidence in the accuracy of the jitter breakdown and bathtub curve
Eye Patterns Show Mask Violations to the Bit
  • Eye pattern measurement on up to 8 million consecutive bits ensures that even transient jitter and noise events are captured
  • Consecutive bit eye pattern analysis allows for the measurement of the wave shapes of individual bits that violate the compliance mask (violation location)
  • The fastest UI accumulation and very low measurement jitter (typically 1 ps rms)
Cable De-embedding
Even expensive, high-performance cabling can have an adverse effect on measurements and steal margin from a design. Cable losses and slow rise times can lead to intersymbol interference that is induced by the measurement system but is not present in the design. The cable de-embedding feature removes these adverse effects leading to more accurate measurements.
Superior Eye Diagram Analysis
SDA II Advanced Debug for Eye and Jitter Analysis
LeCroy''s X-Stream II technology enables unprecedented speed in eye diagram creation. With a 15.3" high definition display and flexible landscape views, the SDA 7 Zi-A provides more insight into eyes than ever before. New features, such as IsoBER, add insight to the traditionally non-quantitative view of eye openings. In addition, properly distinguishing between the random and deterministic jitter in a serial data signal is a crucial part of being able to reduce the overall jitter. For example, properly identifying frequencies at which periodic jitter is present is typically a common part of determining that jitter source. The SDA 7 Zi-A is the only analyzer that fully integrates jitter measurements into the oscilloscope software leading to greater confidence in jitter measurements.
Dual-Eye View Mode
Viewing the Transition and Non-Transition eye diagrams allows for analysis of de-emphasis in serial data waveforms. In addition, Dual-Eye Gated enables the creation of two separate eyes based on a separate signal input (i.e. Read/Write).
Mask Violation Locator
Mask failures are identified by contrasting color spots which appear anywhere the data intersects the mask template. Users can call up the actual stored bit stream waveform at the point in time of the initial failure. The actual bit sequence is also identified, pointing out any ISI problems. Instantly jump to the next violation, or any other within the stored pattern.
IsoBER
Mask testing is not always the best way to determine if the signal is going to meet Bit Error Rate requirements because it lacks quantitative analysis of vertical noise and jitter. LeCroy's unique IsoBER analysis tool provides this quantitative analysis by extrapolating the eye diagram data and displaying the lines of BER directly on the eye. This helps to quickly determine the minimum eye opening and also is instrumental in detecting cross-talk by analyzing the vertical eye closure. These measurements are not possible with standard eye diagram techniques.
More confidence in jitter Breakdown
Simplify Jitter Decomposition
The sources of jitter can be categorized as Deterministic or Random, which is an important distinction in calculating the Total Jitter (TJ) of a signal. There are cases where cross talk, or other types of deterministic jitter, can masquerade as random jitter and cause incorrect calculations. LeCroy's integrated SDA II jitter analysis offers two decomposition algorithms to account for these situations, giving the user confidence that all jitter components are accurately recognized and processed correctly. The jitter decomposition calculates both methods simultaneously and alerts the user only when there is a deviation between the results, giving assurance that the correct jitter values are displayed.
Intuitive Jitter Breakdown Displays
LeCroy's SDA II Serial Data Analysis provides intuitive graphical views of jitter decomposition to quicken insight to the root cause.
To understand deterministic jitter values and their sources, SDA II provides the following tools:
  1. Periodic Jitter Spectrum identifies the sources contributing the highest values of Pj.
  2. ISI Plot isolates bit patterns that contribute the most Intersymbol Interference (ISI)
  3. DDJ Histogram provides a greater understanding of the distributionof Data Dependent Jitter (DDJ)
Setup Warning Indicators
Green / Yellow / Red setup warning indicators alert the user if there is something that requires their attention. For example, if the user's input signal is a clock and they have not selected clock as their signal type, a yellow indicator will be displayed informing the user that they have an inconsistency in the setup that may require their attention.

DDA 7 Zi-A Disk Drive Analyzers - LeCroy Indonesia

Teledyne LeCroy Indonesia

DDA 7 Zi-A Disk Drive Analyzers

Based on the WavePro 7 Zi-A Series models, the DDA 7 Zi-A Series Disk Drive Analyzers are available in 3.5 and 6 GHz models and come equipped with 20 Mpts/ch acquisition memory. Dedicated disk drive measurements, trigger and zooming for failure analysis, and serial data measurement capability with a Disk Drive Analyzer user interface are also standard to address high capacity disk drive designs. Operate in either DDA or SDA mode to analyze the serial data links or the physical media behavior on a hard drive.
Explore DDA 7 Zi-A 

DDA 725Zi-A  (2.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
DDA 735Zi-A  (3.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
DDA 760Zi-A  (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
Check up to three models.
A Total Solution for Disk Drive Analysis
Maximum Performance
LeCroy Disk Drive Analyzers (DDA) assist data storage design engineers by integrating tools that improve the time to market of new products and accelerate understanding and failure analysis on existing drives. LeCroy continues that tradition with the DDA 7 Zi-A Series equipped with its powerful Disk Drive Analysis toolset. Capture, view, and analyze the wave shape of high-speed, complex drive signals with speed and integrity. Data Storage applications are memory intensive as capturing multiple sectors or a complete track of data can be important in troubleshooting a design or characterizing media.
The X-Stream II architecture enables fast and accurate measurements and analysis of disk drive signals. Memory can be extended to 128 Mpts/Ch (256 Mpts/Ch on 2 Ch) using Option L. Both the DDA 760Zi and DDA 735Zi offer the convenience of selectable 50 Ω or 1 MΩ inputs. The standard 20 Mpts of waveform memory and 40 GS/s capture on two channels, means multiple drive sectors can be acquired at once.

Long Memory and Flexibility in Finding Problems
Acquire a head signal up to 6 GHz, and then QuickZoom it from the front panel. The DDA copies and expands the drive signal automatically. Simply scroll horizontally and vertically to examine any sector. Multiple zooms let you view up to eight separate areas of the head signal; each zoom comes in a distinct color. Disk drive parameters let you characterize the pulse width variation or signal-to-noise ratio across a region. Failure Analysis engineers can store and recall golden waveforms and panel setups to compare problem drives with the known good drives. Analog-to-digital converters running at speeds up to 40 GS/s ensure the right sensitivity to measure today's high-speed read channels. In every DDA, you can run your customer-developed scripts to view the captured signal with the filters matched to your channel and media. Custom user scripts can be created in MATLAB, Visual Basic, Excel or other formats.
Exceptional Trigger and Sequence Performance
The DDA's disk triggers allow you to set up a series of events in the signal that then cause a trigger. For example, qualify the signal on the index signal and then capture all the sectors of information on the track. As memory is increased in the DDA, more sectors can be captured, with up to 50 picosecond/sample time resolution. Up to 15,000 sectors of data can be gathered with the DDA 7 Zi-A analyzers. An optional capability, Streaming Sequence, uses the X-Stream II and the fast hardware architecture of the DDA to streamup to 300,000 segments of data to memory; all taken at a high trigger rate.
Natural Graphical Interface
One press on the DDA menu takes you directly to the Disk Drive Analyzer features. The familiar controls on the front panel, coupled with a natural, context-sensitive graphical user-interface, react quickly to your commands. Functionality is exactly where you expect it to be. The DDA 7 Zi-A provides one button access to all the tools needed to accurately debug and analyze disk drive operation.
The DDA 7 Zi-A features:
  • 31 custom parameters
  • 4 specific drive trigger
    • Sector
    • Servo Gate
    • PES trigger
    • Read Gate Trigger
  • Advanced drive analysis tools
Advanced Disk Drive analysis tools capabilities include:
  1. Head Filter Equalizer emulation
  2. Channel Emulation
  3. SAM Histograms
  4. Plot of SAM values
  5. PES runout analysis
  6. Analog Compare
Simultaneously connecting low-speed signals, like index and servo gate, and high-speed signals, like read channels has never been easier. With integrated 50 Ω and 1 MΩ inputs on all models, there is no longer a need for expensive adapters.

HRO 12-bit Oscilloscopes - LeCroy Indonesia

Teledyne LeCroy Indonesia

HRO 12-bit Oscilloscopes

The HRO (High Resolution Oscilloscope) features an industry leading 12-bit Analog to Digital Convertor (ADC), deep memory of 256 Mpts/Ch, and superior DC accuracy specifications.
Explore HRO 12-bit Oscilloscopes 

Check up to three models.


High Resolution Oscilloscopes HRO 64Zi and HRO 66Zi, 400MHz and 600MHz models
The world's clearest and lowest-noise Oscilloscopes are the new HRO models from LeCroy. LeCroy's High Resolution Oscilloscopes combine true 12-bit ADC's and newly designed low-noise front ends to deliver unmatched signal fidelity. From the crisp, ultra-thin traces to the blazing update speed and responsiveness, LeCroy HRO models provide a shocking contrast to traditional 8-bit oscilloscopes.
Superior Validation, Debug, Analysis
LeCroy HRO models contain a powerful feature set which includes a wide range of application packages, advanced triggering to isolate events, a user interface developed for quick and easy navigation, a wide range of probing options, and lightning-fast performance.
Excellent Signal Fidelity
The LeCroy HRO family features a pristine signal acquisition architecture that offers unmatched signal fidelity with low noise. This performance is augmented by a huge offset and timebase delay adjustment to allow easy signal and amplifier performance assessment and zooming on vertical and horizontal signal characteristics.
A New Way to Navigate and View
The WavePilot control area provides convenient control of Cursors, Decode, WaveScan, History, LabNotebook, and Spectrum by their respective function buttons on the front panel.
The SuperKnob is a joystick-like knob in the center of the WavePilot control area used to easily navigate through tables, zoom and position waveforms, and quickly document and annotate your setups.
Simply slide the button on the left side of the display and rotate upwards 90º. The display will automatically change from landscape to portrait mode. The display will also pivot upwards and downwards to optimize viewing angle.
More Trigger Capability Isolates More Problems More Quickly
A powerful combination of high bandwidth edge and 10 different SMART triggers, four stage cascade triggering, measurement trigger, and TriggerScan are all standard and allow you to isolate the problem quickly and begin focus on the cause. The measurement trigger offers a powerful option to qualify a trigger event based on a qualified measurement with great resolution.
Rotating Display
The 12.1" high resolution WXGA wide screen is designed to provide the best view of any signal type on the display.
The widescreen is ideal for a variety of signals where long records are required and zooming or scrolling results in a large block of data.
Rotate the screen 90° degrees to optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequency plots. The screen image will adjust automatically when rotated. Tilt the display up or down in either orientation to minimize reflections or glare.

HDO6000 High Definition Oscilloscopes - LeCroy Indonesia

Teledyne LeCroy Indonesia

HDO6000 High Definition Oscilloscopes

HDO6000 oscilloscopes combine Teledyne LeCroy's HD4096 high definition technology with powerful analysis and debug tools, long memory, in a compact form factor with a 12.1" multi-touch display.
Explore HDO6000 High Definition Oscilloscopes 

Check up to three models.
Key Features
  • 12-bit ADC resolution, up to 15 bits with enhanced resolution
  • 350 MHz, 500 MHz and 1 GHz bandwidths
  • Long Memory - up to 250 Mpts/Ch
  • 12.1" Multi-touch screen display with small footprint
  • Spectrum Analyzer Mode standard
  • WaveScan - Advanced Search and Find
  • History Mode - Waveform Playback
  • Power Analysis Software
  • JITKIT Clock-Data Jitter Analysis
  • Serial Data Trigger and Decode
  • LabNotebook Report Generation
  • Advanced Trigger Tools including TriggerScan and Software Assisted Trigger


HD4096 High Definition Technology
HD4096 high definition technology enables oscilloscopes to capture and display signals of up to 1 GHz with high sample rate and 16 times more resolution than other oscilloscopes.

Benefits of HD4096 Technology
Waveforms captured and displayed on oscilloscopes with HD4096 technology are cleaner and crisper. Signal details often lost in the noise are clearly visible and easy to distinguish HD4096 enables oscilloscopes to deliver unmatched measurement precision for improved debug and analysis.

Touch Screen Simplicity
Easily control channels, trigger, math and measurements with the large multi-touch display and intuitive interface.

Comprehensive Analysis Tools
Comprehensive set of waveform math and measurement tools extends the debugging and analysis capability.

History Mode Waveform Playback
Scroll back in time to isolate anomalies and quickly find the source of the problem.

Identify and Isolate Problems Fast
Quickly locate analog or digital waveforms for runts, glitches or other anomolies with WaveScan

Save, Document, Report
Save all results and data with a single button press and create custom reports with LabNotebook

Spectrum Analyzer Interface
View signal details in the frequency domain with a spectrum analyzer style user interface

Complete Set of Applications
Complete set of solutions available for embedded, digital, power and automotive designs extends analysis

Serial Bus Trigger and Decode
View decoded protocol information on top of physical layer waveforms and trigger on protocol specific messages

Simple Power Measurements
Measure and analyze operating characteristics of power conversion devices and circuits

WaveRunner 6 Zi Oscilloscopes - LeCroy Indonesia

Agen Resmi Teledyne LeCroy Indonesia

WaveRunner 6 Zi Oscilloscopes

The WaveRunner 6 Zi oscilloscope is the most versatile scope in the 400 MHz to 4 GHz class. The performance is unmatched, offering deep memory, 40 GS/s sample rate, low noise and fast operation.
Explore WaveRunner 6 Zi Oscilloscopes 

WaveRunner 640Zi  (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
WaveRunner 625Zi  (2.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
WaveRunner 620Zi  (2 GHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
WaveRunner 610Zi  (1 GHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
WaveRunner 606Zi  (600 MHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
WaveRunner 604Zi  (400 MHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Max Sample Rate)
Quick Specs
 
Check up to three models.
Superior Validation, Debug, Analysis
The WaveRunner 6 Zi defines superiority in a test instrument. The powerful feature set includes a wide range of application packages, advanced triggering to isolate events, a user interface developed for quick and easy navigation, a wide range of probing options, and lightning-fast performance.
WaveRunner 6 Zi Oscilloscope Videos

Most Comprehensive Serial Data Analysis
WaveRunner 6 Zi offers the most tools for serial data analysis. With over 17 trigger, decode, and compliance solutions, WaveRunner 6 Zi can address problems with unique, powerful views and automated tools. The unique measurement toolset, ProtoSync, combines the oscilloscope view with a simultaneous view of data link layer decodes on the same instrument.
Excellent Signal Fidelity
The WaveRunner 6 Zi oscilloscope family features a pristine signal path that offers unmatched signal fidelity with low noise. This performance is augmented by a huge offset and timebase delay adjustment to allow easy signal and amplifier performance assessment and zooming on vertical and horizontal signal characteristics.
A New Way to Navigate and View
The WavePilot control area provides convenient control of Cursors, Decode, WaveScan, History, LabNotebook, and Spectrum by their respective function buttons on the front panel.
The SuperKnob is a joystick-like knob in the center of the WavePilot control area used to easily navigate through tables, zoom and position waveforms, and quickly document and annotate your setups.
Simply slide the button on the left side of the display and rotate upwards 90º. The display will automatically change from landscape to portrait mode. The display will also pivot upwards and downwards to optimize viewing angle.
More Trigger Capability Isolates More Problems More Quickly
A powerful combination of high bandwidth edge and 10 different SMART triggers, four stage cascade triggering, measurement trigger, and TriggerScan are all standard and allow you to isolate the problem quickly and begin focus on the cause. The measurement trigger offers a powerful option to qualify a trigger event based on a qualified measurement with great resolution. A high-speed serial trigger enables triggering on up to 3 Gb/s serial patterns of up to 80-bits in length. A full range of serial triggers (I2C, SPI, UART, RS-232, Audio (I2S, LJ, RJ, TDM), CAN, LIN, FlexRay, MIL-STD-1553, SATA, PCIe, 8b/10b, USB2 and many others) are also available.
Rotating Display
The 12.1" high resolution WXGA wide screen is designed to provide the best view of any signal type on the display.
The widescreen is ideal for a variety of signals where long records are required and zooming or scrolling results in a large block of data.
Rotate the screen 90° degrees to optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequency plots. The screen image will adjust automatically when rotated. Tilt the display up or down in either orientation to minimize reflections or glare.

WaveRunner Xi-A / MXi-A Oscilloscopes - LeCroy Indonesia

Agen Resmi Teledyne LeCroy Indonesia

WaveRunner Xi-A / MXi-A Oscilloscopes

The LeCroy WaveRunner Xi-A is the most powerful and capable scope available in its class. Basic system validation using advanced triggers, fast viewing modes, measurement parameters, or serial decodes is simple and easy. Advanced debug, multi-domain analysis, and waveshape analysis are possible with tools unique to WaveRunner Xi-A. Optional application packages help you make sense of well-defined problems.
Explore WaveRunner Xi-A 

WaveRunner 204MXi-A   (2 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Limited Availability
Quick Specs
 
WaveRunner 204Xi-A   (2 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Limited Availability
Quick Specs
 
WaveRunner 104MXi-A  (1 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
 
WaveRunner 104Xi-A  (1 GHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
 
WaveRunner 64MXI-A  (600 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
 
WaveRunner 64Xi-A  (600 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
 
WaveRunner 62Xi-A  (600 MHz Bandwidth, 2 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
 
WaveRunner 44MXi-A  (400 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
 
WaveRunner44Xi-A  (400 MHz Bandwidth, 4 Input Channels, 5 GS/s Max Sample Rate)
Quick Specs
Check up to three models.
The LeCroy WaveRunner Xi-A is the most powerful and capable scope available in its class. Basic system validation using advanced triggers, fast viewing modes, measurement parameters, or serial decodes is simple and easy. Advanced debug, multi-domain analysis, and waveshape analysis are possible with tools unique to WaveRunner Xi-A. Optional application packages help you make sense of well-defined problems.
Enhanced Understanding of Serial Data Signals
Trigger on I2C, SPI, UART, RS-232, AudioBus (I2S, LJ, RJ, TDM), LIN, CAN, or FlexRay or MIL-STD-1553 serial data patterns. Intuitively decode values on the oscilloscope grid.
Powerful Triggers Isolate Events
An extensive collection of SMART, Serial, and Digital (MS Series) triggers enables users to quickly and easily isolate events of interest (some optional).
WaveStream™ Fast Viewing Mode
Use the high sampling rate and WaveStream fast viewing mode to characterize signal shape, rise time, overshoot, etc., and verify the presence or absence of high-speed transients.
Advanced Acquisition Modes
Sequence Mode allows you to partition your acquisition memory into segments and capture specific events over long periods of time. Then, view and analyze each segment individually.
WaveScan™ Advanced
Search and Analysis WaveScan provides the ability to locate unusual events in a single capture, or scan for an event in many acquisitions over a long period of time using more than 20 different search/scan modes. Use ScanHisto or ScanOverlay to display intuitive scanned results.
Completely Customizable
Quickly create your own measurement parameters or math functions using Excel, MATLAB®, or VBScripts (some capability optional).
Advanced Application Packages
Use a variety of application packages to provide detailed, fast solutions for specific problems.
Fast Long Memory with Front Panel Zoom Controls
WaveRunner Xi-A's long memory is optimized for calculation of more information 10–100x faster than other oscilloscopes, while enabling easy access to simple zooming and positioning from the front panel.
Extensive Math and Measurement Capability
More standard and optional measurements and more powerful math capability are provided with results returned faster than in other oscilloscopes.
Beyond Time Domain Analysis
Amplify your understanding with multidomain analysis of your signals. Convert signal information into Statistical domain (Histogram), Spectral domain (long memory FFTs), Jitter, Modulation, or other Measurement Parameter domains (Tracks of measurement parameters). (Some capability is optional.)
Integrated Tool Sets
LeCroy math, measure, and analysis tools are tightly integrated with basic scope operations. It's easy to link capabilities and expand understanding. Free yourself from constraints!
Complete Probing Solutions
A wide variety of active FET probes, current probes, differential probes, HV probes, etc. with complete tip and ground accessories make it easy to probe your signals.
Mixed Signal Oscilloscope Option
The MS Series can capture digital signals with speeds up to 500 MHz. View up to 36 digital channels with up to 50 Mpts/Ch memory and analyze analog and digital events together.
Power/Amplifier Measurements
Excellent overdrive recovery and signal integrity make WaveRunner Xi-A ideal for high-voltage switching loss, conduction loss, ripple, switching power supply, and other amplifier measurements. Use with LeCroy Differential Amplifiers for highperformance 100,000:1 Common Mode Rejection Ratio.
Timing Characterization
Extensive triggers allow fast event isolation. Measure timing statistically and view behavior graphically using histograms. Gain real understanding of root cause.
Slow/High-speed Signal Mix
Long memory, HFREJ trigger coupling, built-in noise filtering, etc. enable fast understanding of signal behavior in circuits with a mix of slow-speed (sensor, actuator, power supply, mechanical) and high-speed signals.
 
Alamat : Lindeteves Trade Center Lantai UG Jl. Hayam Wuruk,Jakarta. Telp :
Copyright © 2011. Kyoritsu Indonesia by KyoritsuIndonesia - All Rights Reserved.
Mobile/WA : 081297888837
Email : kyoritsu999@gmail.com